SENA ProBee-ZE10 User Manual
Page 60

60
ProBee-ZE10 User Guide Rev.1.5
OK
# Response
AT+REMOTE=9AD6,AT+AI?
# Get all the analog data of Router from remote coordinator
****,****,218F,0D9A
# Analog data of Router
OK
# Response
AT+REMOTE=0001950000000212,AT+AI2?
# Get router’s analog data for temperature from remote coordinator
218F
# Router’s analog data for temperature (Refer to 6.6.7 Data
# Conversion)
OK
# Response
AT+REMOTE=9AD6,AT+AI3?
# Get router’s analog data for illumination from remote coordinator
0D8D
# Router’s analog data for illumination (Refer to 6.6.7 Data
# Conversion)
OK
# Response
6.6.5
Periodic Sampling – Destination Node
6.6.5.1 Coordinator Configuration
The AT commands for Coordinator Configuration:
ATS11=1
# Set coordinator to receive incoming data
OK
# Response
ATZ
# Apply configuration
OK
# Response
6.6.5.2 Router Configuration
The AT commands for Router Configuration:
AT+DESTLA=0001950000001481
# Set coordinator to the destination device to send
# analog data such as temperature, illumination
OK
ATS42=1
# Period to send analog data to destination (unit : second)
OK
# Response
ATS43=0
# Set destination to AT+DESTLA
# ATS43=1 sets destination to sink node
ATZ
# Apply configuration
OK
# Response