beautypg.com

High density dc-dc modules, Output voltage and current ratings, Pin connection – Powersolve PS200W Series User Manual

Page 2: External output trim, Output noise

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

High Density DC-DC Modules

Output Voltage and Current Ratings

Pin

Function

1

+Vin

2

ON/OFF

3

CASE

4

-Vin

5

-Vout

6

-Sense

7

Trim

8

+Sense

9

+Vout

Pin Connection

All dimensions in inches (mm)
Tolerances

Inches

x.xx ±0.02

x.xxx ±0.010

Millimeters x.x ±0.5

x.xx ±0.25

MODEL

INPUT

OUTPUT

OUTPUT

INPUT CURRENT

% EFF.

CAPACITOR

VOLTAGE

VOLTAGE

CURRENT

NO LOAD

FULL LOAD

LOAD max.

PS200W-24S3V3

10-36VDC

3.3VDC

50A

130mA

7.90A

87

10000µF

PS200W-24S05

10-36VDC

5VDC

40A

150mA

9.58A

87

10000µF

PS200W-24S12

10-36VDC

12VDC

16.7A

50mA

9.71A

86

2200µF

PS200W-24S15

10-36VDC

15VDC

13.3A

50mA

9.56A

87

2200µF

PS200W-24S24

10-36VDC

24VDC

8.3A

45mA

9.54A

87

2200µF

PS200W-24S48

10-36VDC

48VDC

4.2A

60mA

9.77A

86

2200µF*

PS200W-48S3V3

18-75VDC

3.3VDC

40A

80mA

3.13A

88

10000µF

PS200W-48S05

18-75VDC

5VDC

40A

80mA

4.68A

89

10000µF

PS200W-48S12

18-75VDC

12VDC

16.7A

60mA

4.74A

88

2200µF

PS200W-48S15

18-75VDC

15VDC

13.3A

60mA

4.72A

88

2200µF

PS200W-48S24

18-75VDC

24VDC

8.3A

60mA

4.72A

88

2200µF

PS200W-48S48

18-75VDC

48VDC

4.2A

50mA

4.83A

87

2200µF*

NOTES:
Nominal Input Voltage 24VDC or 48VDC
The output terminal of 48Vout models requires a minimum capacitor of 47µF to maintain specified regulation.

Mechanical and Connection Details

Remote ON/OFF Control

The PS200W Series allows the user to switch the module on and off electronically with the remote on/off feature.
The PS200W Series are available with “positive logic” or “negative logic” (option).

Logic Table

Logic State

(Pin 2)

Negative

Logic

Positive

Logic

Logic low-

Switch closed

Module on

Module off

Logic high-

Switch open

Module off

Module on

External Output Trim

The output can be trimmed externally (±10%) using a fixed resistor or
a trimpot as shown.

Output Noise

The output noise is measured with a 10µF tantalum and a 1.0µF
ceramic capacitor across the output.