Powersolve SM3300 Series User Manual
Page 4
SPECIFICATIONS
Preliminary version
SM3300
Page 1 - 4
January 2013
SM
18-220
SM
66-AR-110
SM 100-AR-75
SM
330-AR-22
SM 660-AR-11
Hold-Up time
V
out
= 100%,
P
out
= 3300W
I
out
= 100%,
P
out
= 3300W
V
out
= 100%,
P
out
= 1750W
@ 400 V AC in put
6 ms
13 ms
18 ms
12 ms
13 ms
24 ms
12 ms
13 ms
24 ms
12 ms
13 ms
24 ms
12 ms
13 ms
24 ms
Turn on de lay
af ter mains switch on
1.4 s
In rush cur rent
15 A
Se ries op er a tion
max. to tal volt age
Mas ter / Slave op er a tion
4
1000 V
3
yes
1000 V
3
yes
1000 V
3
yes
1330 V
3
yes
1400V
3
yes
Par al lel op er a tion
Nor mal
Mas ter / Slave op er a tion
4
no limit
max. 3 units
Re mote sens ing
max. volt age drop per load lead
2 V
Lim its
Volt age
ad just range
Cur rent
ad just range
0 - 101%
0 - 101%
Po ten ti om eters & Encoders
front panel con trol with knobs
res o lu tion
15 bits.
Me ters
scale
volt age
scale
cur rent
ac cu racy read out put
read limit set ting
(d = digit)
4 digit
0 - 18.00 V
0 - 220.0 A
0.2% + 2 d
0.3% + 2 d
4 digit
0 - 66.00 V
0 - 110.0 A
0.2% + 2 d
0.3% + 2 d
4 digit
0 - 100.0 V
0 - 75.00 A
0.2% + 2 d
0.3% + 2 d
4 digit
0 - 330.0 V
0 - 22.00 A
0.2% + 2 d
0.3% + 2 d
4 digit
0 - 660.0 V
0 - 11.00 A
0.2% + 2 d
0.3% + 2 d
Mount ing
Stack ing of units al lowed, air flow is from left to right.
In put Ter mi nals
Screw Ter mi nals for ca ble 2.5 - 4 mm
2
, 3 phase + earth (no neu tral re quired)
Out put Ter mi nals
M8 bolts
Pro gram ming con nec tor
RJ45-con nec tor for Ethernet (LAN) at rear panel.
In ter lock
In put for con tact at rear panel, see photo of rear panel on page 1-6
Cool ing
au dio noise level
air flow
Low noise blower, fan speed adapts to tem per a ture of in ter nal heatsink.
ca. 50 dBA at full load, 25 °C am bi ent tem per a ture, 1 m dis tance
ca. 57 dBA at full load, 50 °C am bi ent tem per a ture, 1 m dis tance
From left to right
En clo sure
de gree of pro tec tion
IP20
Di men sions
front panel: h x w
be hind front panel: h x w x d
88.1 x 483 mm (19", 2 U)
86 x 433 x 455 mm
with op tional in ter faces, re quired depth is 500...530mm.
Weight
15 kg
Notes: 1. Mea sured at full load
2. Sig nal la tency de pends on the in ter face used and data traffic.
3. See 'Safety In struc tions' in the man ual.
4. With op tional 'plug and play' in ter face. (Not yet avail able)
CV= Con stant Volt age
CC= Con stant Cur rent
Spec i fi ca tions mea sured at
T
amb
= 25 ± 5 °C and Vin = 400 VAC,
50 Hz, 3 phase, un less oth er wise noted.
The in for ma tion in this doc u ment is
sub ject to change with out no tice