Powersolve SM3300 Series User Manual
Page 2
SPECIFICATIONS
Preliminary version
SM3300
Page 1 - 2
January 2013
SM
18-220
SM
66-AR-110
SM
100-AR-75
SM
330-AR-22
SM 660-AR-11
Out put
volt age
cur rent
0 - 18 V
0 - 220 A
0 - 66 V
0 - 110 A
0 - 100 V
0 - 75 A
0 - 330 V
0 - 22 A
0-660V
0-11 A
In put
AC 1 or 3 phase, 48 - 62 Hz
rated volt age range
rated fre quency
rated cur rent
cur rent (400 V / 3 ph, 3300W)
power fac tor, 3300W, 1750W
Power De rat ing vs in put
Sin gle phase:
230 V : P
out max
(W), I
in
(A)
205 V : P
out max
(W), I
in
(A)
180 V : P
out max
(W), I
in
(A)
Three phase
190 V : P
out max
(W), I
in
(A)
180 V : P
out max
(W), I
in
(A)
power fac tor sin gle phase
in ter nal fuses
standby in put power (V
o
=I
o
=0)
standby in put power (V
o
=V
max
)
180-528
V
200 - 480 V
50 / 60 Hz
Max. 16 A
5.8 A
0.94, 0.92
3050, 16
2650, 16
2300, 16
3300, 12.5
3100, 12.5
0.99
20 AT
30 W
60 W
180-528
V
200 - 480 V
50 / 60 Hz
Max. 16 A
5.6 A
0.94, 0.92
3100, 16
2700, 16
2400, 16
3300, 12.5
3100, 12.5
0.99
20 AT
30 W
50 W
180-528
V
200 - 480 V
50 / 60 Hz
Max. 16 A
5.6 A
0.94, 0.92
3100, 16
2700, 16
2400, 16
3300, 12.5
3100, 12.5
0.99
20 AT
30 W
50 W
180-528
V
200 - 480 V
50 / 60 Hz
Max. 16 A
5.6 A
0.94, 0.92
3200, 16
2800, 16
2400, 16
3300, 12.5
3100, 12.5
0.99
20 AT
30 W
50 W
180-528
V
200 - 480 V
50 / 60 Hz
Max. 16 A
5.6 A
0.94, 0.92
3200, 16
2800, 16
2400, 16
3300, 12.5
3100, 12.5
0.99
20 AT
30 W
60 W
Ef fi ciency
400 V AC, 3 ph in put, full load
89 %
90 %
90 %
91 %
92 %
Reg u la tion
Load 0 - 100%
CV
Line 180 - 528 V AC
CV
(ex ter nal volt age sense)
2.5 mV
0.2 mV
5 mV
1 mV
5 mV
1 mV
5 mV
3 mV
5 mV
4 mV
Load 0 - 100%
CC
Line 180 - 528 V AC
CC
(in ter nal volt age sense,
af ter warm-up)
12 mA
3 mA
6 mA
1 mA
2 mA
0.5 mA
1.2 mA
0.2 mA
1.2 mA
0.2 mA
33 / 66 V
50 / 100 V
165 / 330 V
330 / 660 V
Rip ple + noise
rms
(BW=300 kHz) CV
p-p
(BW=20 MHz) CV
rms
(BW=300 kHz) CC
p-p
(BW=20 MHz) CC
CC-rip ple at full load
3 mV
12 mV
50 mA
250 mA
7 mV
18 mV
15 / 7.5 mA
90 / 45 mA
7 mV
22 mV
6 / 2 mA
60 / 20 mA
10 mV
50 mV
4.5 / 1.5 mA
24 / 8 mA
15 mV
120 mV
1.8 / 0.6 mA
7.5 / 2.5 mA
Temp. coeff., per °C
1
CV
CC
35.10
-6
60.10
-6
Sta bil ity
1
af ter 1 hr warm-up
dur ing 8 hrs
CV
CC
t
amb
= 25 ± 1 °C, V
in
= 400 V AC
in ter nal volt age sens ing for CC-stab.
6.10
-5
9.10
-5
Pro gram ming speed
2
Stan dard Ver sion
(re sis tive load)
SM
18-220
SM
66-AR-110
SM 100-AR-75
SM
330-AR-22
SM 660-AR-11
Rise time (10 - 90%)
out put volt age step
time, (load = 3300 W)
time, (load = 330 W)
out put volt age step
time, (load = 3300 W)
time, (load = 330 W)
0 → 15 / 18 V
4 / 5.5 ms
2.2 / 2.6 ms
-
-
-
0 → 33 V
1.6 ms
1 ms
0 → 66 V
7 ms
3.7 ms
0 → 50V
3.6 ms
2 ms
0 → 100 V
15 ms
8 ms
0 → 165 V
3.8 ms
2 ms
0 → 330 V
15 ms
8 ms
0 → 330 V
4.2 ms
2.5 ms
0 → 660 V
15 ms
7.5 ms