beautypg.com

Powersolve SM3300 Series User Manual

Page 2

background image

SPECIFICATIONS

Preliminary version

SM3300

Page 1 - 2

January 2013

SM

18-220

SM

66-AR-110

SM

100-AR-75

SM

330-AR-22

SM 660-AR-11

Out put

volt age
cur rent

0 - 18 V

0 - 220 A

0 - 66 V

0 - 110 A

0 - 100 V

0 - 75 A

0 - 330 V

0 - 22 A

0-660V

0-11 A

In put

AC 1 or 3 phase, 48 - 62 Hz

rated volt age range
rated fre quency
rated cur rent

cur rent (400 V / 3 ph, 3300W)
power fac tor, 3300W, 1750W

Power De rat ing vs in put
Sin gle phase:
230 V : P

out max

(W), I

in

(A)

205 V : P

out max

(W), I

in

(A)

180 V : P

out max

(W), I

in

(A)

Three phase
190 V : P

out max

(W), I

in

(A)

180 V : P

out max

(W), I

in

(A)

power fac tor sin gle phase

in ter nal fuses
standby in put power (V

o

=I

o

=0)

standby in put power (V

o

=V

max

)

180-528

V

200 - 480 V

50 / 60 Hz
Max. 16 A

5.8 A

0.94, 0.92

3050, 16
2650, 16
2300, 16

3300, 12.5
3100, 12.5

0.99

20 AT

30 W
60 W

180-528

V

200 - 480 V

50 / 60 Hz
Max. 16 A

5.6 A

0.94, 0.92

3100, 16
2700, 16
2400, 16

3300, 12.5
3100, 12.5

0.99

20 AT

30 W
50 W

180-528

V

200 - 480 V

50 / 60 Hz
Max. 16 A

5.6 A

0.94, 0.92

3100, 16
2700, 16
2400, 16

3300, 12.5
3100, 12.5

0.99

20 AT

30 W
50 W

180-528

V

200 - 480 V

50 / 60 Hz
Max. 16 A

5.6 A

0.94, 0.92

3200, 16
2800, 16
2400, 16

3300, 12.5
3100, 12.5

0.99

20 AT

30 W
50 W

180-528

V

200 - 480 V

50 / 60 Hz
Max. 16 A

5.6 A

0.94, 0.92

3200, 16
2800, 16
2400, 16

3300, 12.5
3100, 12.5

0.99

20 AT

30 W
60 W

Ef fi ciency

400 V AC, 3 ph in put, full load

89 %

90 %

90 %

91 %

92 %

Reg u la tion

Load 0 - 100%

CV

Line 180 - 528 V AC

CV

(ex ter nal volt age sense)

2.5 mV
0.2 mV

5 mV
1 mV

5 mV
1 mV

5 mV
3 mV

5 mV
4 mV

Load 0 - 100%

CC

Line 180 - 528 V AC

CC

(in ter nal volt age sense,
af ter warm-up)

12 mA

3 mA

6 mA
1 mA

2 mA

0.5 mA

1.2 mA
0.2 mA

1.2 mA
0.2 mA

33 / 66 V

50 / 100 V

165 / 330 V

330 / 660 V

Rip ple + noise

rms

(BW=300 kHz) CV

p-p

(BW=20 MHz) CV

rms

(BW=300 kHz) CC

p-p

(BW=20 MHz) CC

CC-rip ple at full load

3 mV

12 mV

50 mA

250 mA

7 mV

18 mV

15 / 7.5 mA

90 / 45 mA

7 mV

22 mV

6 / 2 mA

60 / 20 mA

10 mV
50 mV

4.5 / 1.5 mA

24 / 8 mA

15 mV

120 mV

1.8 / 0.6 mA
7.5 / 2.5 mA

Temp. coeff., per °C

1

CV
CC

35.10

-6

60.10

-6

Sta bil ity

1

af ter 1 hr warm-up

dur ing 8 hrs

CV
CC

t

amb

= 25 ± 1 °C, V

in

= 400 V AC

in ter nal volt age sens ing for CC-stab.

6.10

-5

9.10

-5

Pro gram ming speed

2

Stan dard Ver sion

(re sis tive load)

SM

18-220

SM

66-AR-110

SM 100-AR-75

SM

330-AR-22

SM 660-AR-11

Rise time (10 - 90%)

out put volt age step

time, (load = 3300 W)
time, (load = 330 W)

out put volt age step

time, (load = 3300 W)
time, (load = 330 W)

0 → 15 / 18 V

4 / 5.5 ms

2.2 / 2.6 ms

-
-
-

0 → 33 V

1.6 ms

1 ms

0 → 66 V

7 ms

3.7 ms

0 → 50V

3.6 ms

2 ms

0 → 100 V

15 ms

8 ms

0 → 165 V

3.8 ms

2 ms

0 → 330 V

15 ms

8 ms

0 → 330 V

4.2 ms
2.5 ms

0 → 660 V

15 ms

7.5 ms