beautypg.com

Powersolve JB200 Series User Manual

Ac-dc converters

background image

www.powersolve.co.uk

Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

AC-DC Converters

JB200 Redundant Series

200 Watts

Single Output

Switching Power Supply

Features

Providing Peak Power of 600W within 500uS duty duration

Compact 1U Height & Power Density: 5.16 watts/cu in

Power factor corrected to EN61000-3-2 class A

Approved to UL CUL TUV CB and CE

AC input range auto-selectable

N+1 parallel redundancy

Optional Top Cover

Input Voltage:

90-132 / 180-264Vac, 47-63HZ auto selectable.

Input Current:

5/2.5A at 115/230VAC.

Inrush Current:

Max. 70A@230Vac & 35A@115Vac; cold start.

PFC:

Power factor correction to EN61000-3-2 class A (total parallel output power not exceeding 200W).

Transient Response:

Output voltage returns to within 1% in less than 2.5mS for a 50% load change, peak does not exceed 5%.

Overshoot:

Turn-on & off overshoot < 5% over nominal voltage.

Efficiency:

70% for 3.3V, 75% for 5V, 80% for 12V and 83% minimum for other outputs @ 230V and full load.

Turn On Delay:

1 second maximum at 120 VAC.

Hold Up Time:

20mS min. at120Vac & 80% of full load.

Adjustability:

Output user adjustable +/-5% minimum.

Input Fusing Protection:

One T5A/250V fuse inserted in primary.

Over-Voltage Protection:

Unit latches down when output exceeds 130% and recycle AC input to reset.

Over-Power Protection:

Fold back mode 110-135%; Auto-recovery.

Short-Circuit Protection:

Trip without damage and auto-recovery.

Over-Temperature Protection: Unit protected against excessive operating ambient of 85 °C, and automatic recovery.
Switching Frequency:

25KHZ fixed frequency.

Operating Temperature:

0 to 40 degrees C.

Storage Temperature:

-20 to 85 degrees C.

Operating Humidity:

5% to 90% RH, Non-condensing.

Storage Humidity:

5% to 95% RH, Non-condensing.

Vibration:

Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on X,Y and Z Axis.

Remote On-Off:

Designated as REMO on the CN3. Requires a low signal to inhabit output; Hiccough mode.

Power Supply On:

Green LED designated as LED1 on the PCB.

Power Good:

Designated as PG on the CN3 will go high 100-500 mS after regulation and goes low 1mS before loss of regulation.

Fan Drive:

12VDC/300 mA is available to drive an external fan.

EMC Standards:

CISPR 22 / EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN55024 CE Marked (LVD).

Safety Regulation:

Approved to UL60950-1, CSA C22.2 No. 60950- 1, TUV EN60950-1 and CB certificate available.

Leakage Current:

1.5mA @ 240Vac.

HI-POT Test:

1500 VAC input line to chassis (10mA DC cut off current);
Isolating 3000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.

Grounding Test:

Apply 25 A from ground pin of the three prong plug to the far most earth. Max allowable resistance 0.1 ohm.

MTBF:

100000 Hrs (according to MIL-HBK-217F) at 30 degree C.

Cooling:

200W max. with 18.7cfm airflow or 150W max convection.

Enclosure:

6.8(L) x 3.8(W) x 1.5(H) inches; U-Chassis Type.

Weight:

Maximum weight is 600g.

Electrical Specification

Overall Size: 6.8(L) x 3.8(W) x 1.5(H)inches