Powersolve XC Series User Manual

6.0 kva, Xc series, Ups cabinet

background image

www.powersolve.co.uk

Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

Specification

1.5-6.0 kVA

True On-Line UPS

Complete UPS Cabinet

Single / Dual Mains Input Option

Internal Maintenance Bypass Switch Option

LCD Load Segment Control 2.5 kVA & 3.0 kVA

Optional 10 Year Batteries

XC Series

Input

Input Voltage (full load

• 115 VAC version, 80-138 V

without using battery)

208 VAC version, 176-276 V
230 VAC version, 176-276 V

Input Frequency

• 46-64 Hz

Input Power Factor

• <0.98 at full load

Input Protection

• Fuse/Breaker

Output

Output Voltage

• 115 VAC nominal -

100/110/115/120 VAC selectable
208 VAC nominal -
208/220/230/240 VAC selectable
230 VAC nominal -
208/220/230/240 VAC selectable

Output Regulation

• ±2% of nominal

Output Waveform

• Sine wave

Output THD

• <3%, linear load

Crest Factor

• 3:1

Output Protection

• Electronic overload protection

(ultimately by fuse/breaker)

Efficiency (AC-AC)

• 86% up to 1.5 kVA, 90% up to 6.0 kVA

Overload Capacity

• See Xi Datasheet

Output Frequency

• 50/60 Hz dependent on input

Battery

Internal Battery Type

• VRLA 5 year design life standard,

10 year design life option available

Battery Replacement

• Hot-swap all models

Recharge

• <4 hours to 90%, standard battery only

Battery String Voltage

• 48 VDC: 1.5 kVA

96 VDC: 2.5-3.0 kVA
192 VDC: 4.0-6.0 kVA

Autonomy

• See Xi Datasheet

Temperature

• Autonomy, recharge and battery life

based on +25 ºC ambient

1

General

Input/Output Terminals • Suitable for cable up to 10 mm

2

Display/Alarm

• Front panel LCD menu driven, audible

alarms. See System Layout

Interface

• VFC Standard (AS400) providing remote

indication of: UPS AC Input OK/ UPS AC
Input

Failure

• Battery OK/ Battery Low UPS OK/

UPS Alarm On Inverter /UPS Bypassed
RS232 or USB option available

REPO

• Remote emergency power off, must be

fitted for unit to function. Remove link to
shut down output in AC mode or shut
down unit in battery mode

Mechanical (h x w x d)

• Small - 1200 mm x 600 mm x 800 mm

Medium - 1700 mm x 600mm x 800 mm
Large - 2100 mm x 600 mm x 800 mm
Bottom entry as standard
Front & rear lockable access
(standard system requires rear access)

Environmental

Operating Temperature • 0 ºC to +40 ºC

Storage Temperature

• -15 ºC to +50 ºC

Cooling

• Fan assisted cooling fitted to all cabinets

as standard

Operating Humidity

• 0-95% RH, non-condensing

Operating Altitude

• 3000 metres without derating

Acoustic Noise

• <45 dBA at 1 metre

Ingress Protection

• Options from IP21 - IP54

EMC & Safety

Emissions

• EN55022 level B,

EN50091-2, level B, FCC Class B

ESD Immunity

• EN61000-4-2, level 3

Radiated Immunity

• EN61000-4-3, level 2

EFT/Burst

• EN61000-4-4, level 2

Surge

• EN61000-4-5, level 3

Safety Approvals

• EN50091-1-1, EN60240-1-1, EN60950, CE

UPS CABINET