beautypg.com

System specifications – GE P&W Ultrapure and Drinking Water TOC Analyzers - Sievers 500 RLe Brochure User Manual

Page 4

background image

©2012, General Electric Company. All rights reserved.

Europe/Middle East/Africa

GE Analytical Instruments

Unit 3, Mercury Way

Urmston, Manchester

UK M41 7LY

T +44 (0) 161 864 6800

F +44 (0) 161 864 6829

[email protected]

The Americas

GE Analytical Instruments

6060 Spine Road

Boulder, CO 80301-3687 USA

T +1 800 255 6964

T +1 303 444 2009

F +1 303 527 1797

[email protected]

Asia Pacific

GE Analytical Instruments

7/F, Building 2, No. 5 Hua Tuo Rd

ZhangJiang Hi-Tech Park, Pudong

Shanghai, China 201203

T +(8621) 38777775

F +(8621) 38777469

[email protected]

www.geinstruments.com

ISO

9001:2008

QUALITY

MANAGEMENT

SYSTEM

*Trademark of General Electric Company; may be registered in one or more countries.
**Stated analytical performance is achievable under controlled conditions that minimize operator and standards errors.

The Sievers 500 RL TOC Analyzers are protected by one or more of the following US and foreign patents: US 8,003,048; US 5,976,468; US 5,837,203; US 5,443,991; EP
0897530; FR 0897530; GB 0897530; DE 69702516.0-08. Other patents pending.

For more information, visit www.geinstruments.com. Find a sales partner near you through the “Contact Us” Section.

System Specifications**

Total Organic Carbon

Range

0.03 to 2,500 ppb as C

Accuracy

± 0.1 ppb or ± 5% of measurement, whichever is greater

Precision

< 1% RSD or 0.03 ppb as C, whichever is greater

pH Range

5.5 to 8.0 in order to meet accuracy specification

Maximum Sample Conductivity

25 µS/cm at neutral pH

Analysis Modes

On-Line, On-Line Averaged, On-Line Timed

Analysis Time

Continuous mode: 6 minutes

Average and timed modes: 0.5, 1, 4, 8, or 24 hours

External Flow Rate

Minimum 50 mL/min

Sample Temperature

1° C to 95° C (34° F to 203° F)

Sample Pressure

Up to 100 psig

Interferences

Insensitive to organic heteroatoms and measures

organic nitrogen

Calibration Stability

Typically stable for 12 months

Display Readout

3 significant digits

Instrument

Power

100–240 ±10% VAC, 50 W, 50/60 Hz

Normal Operating Environment

Intended for indoor use only

Ambient Temperature

10° C to 40° C (50° F to 104° F)

Maximum Relative Humidity

Up to 95%, noncondensing

Maximum Altitude

2,300 m (7,546 ft)

Inputs

One isolated binary input

Outputs

Three isolated 4-20 mA outputs, one Serial (RS-232), one USB

port, one parallel printer port, four alarm outputs, and one

Ethernet port

Installation/Overvoltage

Category II (protects against transients present in Category II power)

Safety Certifications

ETL, CE

Pollution Degree

2 (normally only non-conductive pollution)

Display

Backlit Quarter-VGA touchscreen display

Dimensions

H: 41.9 cm (16.5 in); W: 48.3 cm (19 in); D: 27.4 cm (10.8 in)

Weight

16.9 kg (37.2 lb)

IP Rating

Environmental enclosure: IP 45

Consumables

UV Lamp

6 months

Pump Tubing (with pump heads)

12 months

DI Water Cartridge

Typically 24 months (depends on water quality)

Inline filter

Replace as needed (depends on water quality)

DI Water Level Refill

As needed (check when replacing other items)

300 00165 Rev E