System specifications – GE P&W Ultrapure and Drinking Water TOC Analyzers - Sievers 500 RLe Brochure User Manual
Page 4

©2012, General Electric Company. All rights reserved.
Europe/Middle East/Africa
GE Analytical Instruments
Unit 3, Mercury Way
Urmston, Manchester
UK M41 7LY
T +44 (0) 161 864 6800
F +44 (0) 161 864 6829
The Americas
GE Analytical Instruments
6060 Spine Road
Boulder, CO 80301-3687 USA
T +1 800 255 6964
T +1 303 444 2009
F +1 303 527 1797
Asia Pacific
GE Analytical Instruments
7/F, Building 2, No. 5 Hua Tuo Rd
ZhangJiang Hi-Tech Park, Pudong
Shanghai, China 201203
T +(8621) 38777775
F +(8621) 38777469
www.geinstruments.com
ISO
9001:2008
QUALITY
MANAGEMENT
SYSTEM
*Trademark of General Electric Company; may be registered in one or more countries.
**Stated analytical performance is achievable under controlled conditions that minimize operator and standards errors.
The Sievers 500 RL TOC Analyzers are protected by one or more of the following US and foreign patents: US 8,003,048; US 5,976,468; US 5,837,203; US 5,443,991; EP
0897530; FR 0897530; GB 0897530; DE 69702516.0-08. Other patents pending.
For more information, visit www.geinstruments.com. Find a sales partner near you through the “Contact Us” Section.
System Specifications**
Total Organic Carbon
Range
0.03 to 2,500 ppb as C
Accuracy
± 0.1 ppb or ± 5% of measurement, whichever is greater
Precision
< 1% RSD or 0.03 ppb as C, whichever is greater
pH Range
5.5 to 8.0 in order to meet accuracy specification
Maximum Sample Conductivity
25 µS/cm at neutral pH
Analysis Modes
On-Line, On-Line Averaged, On-Line Timed
Analysis Time
Continuous mode: 6 minutes
Average and timed modes: 0.5, 1, 4, 8, or 24 hours
External Flow Rate
Minimum 50 mL/min
Sample Temperature
1° C to 95° C (34° F to 203° F)
Sample Pressure
Up to 100 psig
Interferences
Insensitive to organic heteroatoms and measures
organic nitrogen
Calibration Stability
Typically stable for 12 months
Display Readout
3 significant digits
Instrument
Power
100–240 ±10% VAC, 50 W, 50/60 Hz
Normal Operating Environment
Intended for indoor use only
Ambient Temperature
10° C to 40° C (50° F to 104° F)
Maximum Relative Humidity
Up to 95%, noncondensing
Maximum Altitude
2,300 m (7,546 ft)
Inputs
One isolated binary input
Outputs
Three isolated 4-20 mA outputs, one Serial (RS-232), one USB
port, one parallel printer port, four alarm outputs, and one
Ethernet port
Installation/Overvoltage
Category II (protects against transients present in Category II power)
Safety Certifications
ETL, CE
Pollution Degree
2 (normally only non-conductive pollution)
Display
Backlit Quarter-VGA touchscreen display
Dimensions
H: 41.9 cm (16.5 in); W: 48.3 cm (19 in); D: 27.4 cm (10.8 in)
Weight
16.9 kg (37.2 lb)
IP Rating
Environmental enclosure: IP 45
Consumables
UV Lamp
6 months
Pump Tubing (with pump heads)
12 months
DI Water Cartridge
Typically 24 months (depends on water quality)
Inline filter
Replace as needed (depends on water quality)
DI Water Level Refill
As needed (check when replacing other items)