beautypg.com

GE P&W Tonkaflo - PROPAK NA Series User Manual

Propak* na series, Features, System operating parameters

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

PROPAK, Patent Pending

©2013, General Electric Company. All rights reserved.

AM-FSpwPROPAK-NA_EN.doc Jun-13

PROPAK* NA Series

Integrated UF RO Platforms 100-200-300 gpm (60 Hz)







Features

Single compact multifunctional Tank: Break, UF
backwash, UF CIP, RO CIP.

Integrated control with single Allen Bradley PLC
and HMI (Ethernet communications)

4-20 mA instruments

RO permeate flush on shutdown

UF backwash/CIP pump, RO feed pump
(mounted on the tank skid), RO High pressure
pump (mounted on filtration skid)

UL/cUL Electrical Panel

System Operating Parameters

Max Design Recovery

1

...................................................... 75%

Max Design Recovery

1

(with ICR) ................................. 85%

Design Temperature ............................................ 60°F (15°C)
Operating Temperature Range ....... 59-85ºF (15-29ºC)
Nominal RO rejection ................................................ 97-99%
System Inlet Pressure ............. 10-65 PSIG (0.7-4.5 bars)
UF average membrane flux ....................................... 45 gfd
RO average membrane flux....................................... 20 gfd

1

Recovery Rate can vary +/- 5%

Available Options

ICR (Integral Concentrate Recovery)

UF flow control valve or UF Feed Pump

Motor Starter (RO Feed, RO HP Pumps)

VFD (UF Feed, UF backwash/CIP, RO HP Pumps)

UF backwash aeration Blower and VFD

500 micron automated pre-screen

UF modules membrane integrity test

Instrumentation

Flow Meters:................................. UF Feed, UF CIP/BW, RO

Permeate, RO concentrate, ICR Permeate

Conductivity Meter: .................... RO Feed, RO Permeate,

ICR Permeate

pH Meter ............................................... UF CIP, RO Feed (opt)
Pressure Transmitters ................ UF Feed, UFPermeate,

RO Primary, RO Final

Pressure Gauges

UF Feed, UF Permeate,

UFBW/CIP pump discharge, RO feed pump dis-

charge, RO pre&post cartridge filter;

RO HP pump discharge/primary/final,

RO interstage/permeate/concentrate to drain

Pressure Switch ............UF Feed / Backwash, RO Feed,

RO Permeate, RO Concentrate, ICR Permeate

Chlorine Meter .................................................... UF Permeate
ORP ..................................................................................... RO Feed
Temperature....................... UF Permeate, RO Feed, Tank
Turbidity Meter ............................... UF Feed, UF Permeate
Level Transmitter ............................................................... Tank

Materials of Construction

High-pressure piping ........ 316 Stainless Steel, Sch. 10
Low-pressure piping .........................................PVC, Sch. 80
Frame ........................................... Painted blue carbon steel
Enclosure .......................................................................... Nema 4
Clamps/fittings ...................................................... Zinc-plated
Cartridge housing ................................ 316 Stainless Steel

Membrane Elements and Housings

RO Membrane ................................................. AG8040F-400
Style ............... Spiral-wound elements, TFC (polyamide)
Membrane rejection ...................................... 99.0 to 99.5%
RO Membrane Housing ............................................ GE, FRP
Housing Pressure Rating ........................................ 450 psi
UF Membrane Model .......................................... GE ZW1500
UF Membrane Surface ................................................ 550 ft2