beautypg.com

GE P&W Tonkaflo - MUNI Series 60 Hz User Manual

Muni series 60 hz, Features, Instrumentation

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1654EN.doc Jul-13



MUNI Series 60 Hz

Reverse Osmosis & Nanofiltration Machines
50 gpm to 1 mgd (11.4 to 157.8 m

3

/hr)

Features

GE Fanuc Quickpanel, 12.0-inch color display, text
and pictorial operating screens, touchscreen con-
trols

GE Fanuc Versamax, communication: Ethernet

4-20 mA instruments on QuickPanel

Primary and final pressure transmitters

UL 508 listed

Instrumentation

Flow Meters ............................................ Permeate, concentrate
Conductivity ........................................................... Feed, Permeate
pH ........................................................................................................ Feed
Pressure Gauges .......................... Pre-filter, post-filter, pump

discharge, primary, interstage,

final concentrate, permeate

Pressure Transmitters................. Pump discharge, primary,

interstage, final concentrate, permeate

Pressure Switch ....................................................... Low feed,High

permeate, concentrate

ORP ..................................................................................................... Feed
Instrument Center ......................................... Thornton 770 Max

Options Available

Allen-Bradley Control Package

Soft Starters

Variable Frequency Drives

SCADA: 75pt trending package with desktop PC

Electric-actuated operating valves

MUNI Multi-Media filters

MUNI Clean-in-Place units

MUNI chemical feed systems

Transfer pumps and storage tanks

Documentation Included

Operation and maintenance manual

Drawings: piping and instrumentation, electrical
and general dimensional

Operating Parameters

Typical feedwater recovery rate ................................75-85%
Design temp. .............................................................. 60ºF (15.6ºC)
Typical operating range ............. 35 to 85ºF (1.6 to 29.4ºC)
Nominal membrane rejection % ....... Membrane Specific
Minimal inlet pressure .......................................................... 30 psi

Materials of Construction

High-pressure piping .............. 316 Stainless Steel, Sch. 10
Low-pressure piping ............................................... Sch. 80, PVC
Frame ................................................. Painted blue carbon steel
Enclosure .............................................. NEMA 12 (painted blue)
Clamps/fittings............................................................. Zinc-plated

Membrane Elements & Housings

Membrane Model .................................. MUNI–RO-400-HR-LE
Style ......................................................... Spiral-wound elements
Manufacturer ................................................................................... GE