GE P&W Tonkaflo - MUNI Series 60 Hz User Manual
Muni series 60 hz, Features, Instrumentation
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1654EN.doc Jul-13
MUNI Series 60 Hz
Reverse Osmosis & Nanofiltration Machines
50 gpm to 1 mgd (11.4 to 157.8 m
3
/hr)
Features
GE Fanuc Quickpanel, 12.0-inch color display, text
and pictorial operating screens, touchscreen con-
trols
GE Fanuc Versamax, communication: Ethernet
4-20 mA instruments on QuickPanel
Primary and final pressure transmitters
UL 508 listed
Instrumentation
Flow Meters ............................................ Permeate, concentrate
Conductivity ........................................................... Feed, Permeate
pH ........................................................................................................ Feed
Pressure Gauges .......................... Pre-filter, post-filter, pump
discharge, primary, interstage,
final concentrate, permeate
Pressure Transmitters................. Pump discharge, primary,
interstage, final concentrate, permeate
Pressure Switch ....................................................... Low feed,High
permeate, concentrate
ORP ..................................................................................................... Feed
Instrument Center ......................................... Thornton 770 Max
Options Available
Allen-Bradley Control Package
Soft Starters
Variable Frequency Drives
SCADA: 75pt trending package with desktop PC
Electric-actuated operating valves
MUNI Multi-Media filters
MUNI Clean-in-Place units
MUNI chemical feed systems
Transfer pumps and storage tanks
Documentation Included
Operation and maintenance manual
Drawings: piping and instrumentation, electrical
and general dimensional
Operating Parameters
Typical feedwater recovery rate ................................75-85%
Design temp. .............................................................. 60ºF (15.6ºC)
Typical operating range ............. 35 to 85ºF (1.6 to 29.4ºC)
Nominal membrane rejection % ....... Membrane Specific
Minimal inlet pressure .......................................................... 30 psi
Materials of Construction
High-pressure piping .............. 316 Stainless Steel, Sch. 10
Low-pressure piping ............................................... Sch. 80, PVC
Frame ................................................. Painted blue carbon steel
Enclosure .............................................. NEMA 12 (painted blue)
Clamps/fittings............................................................. Zinc-plated
Membrane Elements & Housings
Membrane Model .................................. MUNI–RO-400-HR-LE
Style ......................................................... Spiral-wound elements
Manufacturer ................................................................................... GE