GE P&W E-Series L User Manual
E-series l, Large reverse osmosis machines, 3 to 23 m, General properties
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FS1145EN.doc Jul-13
E-Series L
Large Reverse Osmosis Machines, 3 to 23 m
3
/hr
Figure 1: E4H-CE-L, 3 to 7 cubic meters per hour
Figure 2: E8-CE-L, 9 to 23 cubic meters per hour
GE Water & Process Technologies has more than 30
years experience in designing and building high
quality reverse osmosis systems. Our E-series RO
machines (Figures 1 and 2) are designed for durable
operation, high quality product water production,
easy installation and straightforward control.
E-Series-CE-L machines are designed in 2 versions
of operating temperatures: 25°C and 13°C (CW).
General Properties
Typical Applications
Boiler feed water
Ion exchange pre-treatment
Process ingredient water
Features
Low Energy High Rejection membrane elements
Micron rated pre-filter
Automatic inlet shut-off valve
Permeate purge on shut down (can be disabled)
Emergency stop and motor thermal protection
Instrumentation and Controls
PLC based control system
Two-source power connection for Motor starter
and for Control Panel
Permeate and concentrate flow meters
Digital permeate conductivity meter
Digital pH meter
ALARMS: Low inlet pressure, motor starter
overload, high temperature (38°C), high
permeate conductivity, High permeate
pressure, high pH
Remote machine on/off capability
Pre-filter, post-filter, pump discharge, primary,
and final pressure gauges
Table 1: Operating Parameters
Operating Pressure
8-16 bars
Operating Pressure (CW)
15-22 bars
Maximum Recovery
75%
Nominal Rejection
98% - 99.5%
Typical operating Temperature
10-30
C
Minimum Inlet Pressure
2 bars
Design Temperature**
25
C
Design Temperature** (CW)
13°C
Design Salinity
2,000ppm NaCl
** Varying the operating temperature will affect machine productivity