beautypg.com

1b 1b-1, 1b-2, Warning – Peerless-AV GC-X360S-W - Installation User Manual

Page 8

background image

8

date:01/22/13 #:125-9401

ENG • When installing Peerless wall mounts on a concrete wall, the wall must be at least 8” thick with a minimum

compressive strength of 2000 psi.

• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90

specifications and have a minimum nominal width of 8”. Do not drill into mortar joints! Be sure to mount in a solid

part of the block, generally 1” (25 mm) minimum from the side of the block. It is suggested that a standard electric

drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole

when entering a void or cavity.

• Never attach expansion anchors to concrete or cinder block covered with plaster, drywall or other finishing

material.

WARNING

1b

1b-1

Level cover plate. Mark mounting holes.

1b-2

5/16"

(8mm)

Do not drill into mortar joints.

Drill mounting holes into supporting surface

(2.5" (64 mm) minimum depth required).

2.5"

(64mm)

5/16"

(8mm)