Command

Description

BER and other information. Requires an SFP with DDMI.

unit

Unit global settings, frame size selection. Unit OAM enable must be enabled
for AH and AG to function.

port

Displays the port status and allows changes to port settings, such as duplex
status and speed.

Cleandb

Entering cleandb reboots the unit with its database cleaned depending on the option
selected. Users are presented with two, sequential options, first to reset all SNMP
settings and, second, to reset all of the unit’s configuration to default. Enabling the
first option presents the second. Resetting the unit to factory default values (option
two) will delete all custom IP and other configurations performed through iView².

Downloading Files

Firmware and/or saved configuration data for the IE-iMcV-MultiWay can be
downloaded via a TFTP connection from a central server via TFTP protocol. Initiate
this download via serial configuration or Telnet session. To download a configuration
file, type download and press Enter to be taken to the Download a file screen. This
screen displays the IP Address of the TFTP server and the name of the file to be
downloaded:

The TFTP server should be open. Press Enter to start downloading the file.

After the transfer process is complete, press Enter to load the configuration file: