B&B Electronics 856-19717--57 - Manual User Manual
Page 15

12
Command List
I
= Enter New Saved Parameter Values
P
= Change
Password
T
= New
Trap
Destination
K
= Remove ALL Trap Destinations
C
= New Community String
U
= Delete ALL Community Strings
E
= End
Session
Reboot
= Reboots the IE-MiniFiberLinX-II
D
= Enable/disable
DHCP
Space Bar
= Opens the Device Specific Configuration Options
Assigning TCP/IP Information
To modify the Saved Parameter Values (i.e., assign IP address and subnet mask), and
press I. Then, enter the IP address and subnet mask for the connected device,
pressing Enter after each. A default gateway can also be assigned, or press Enter to
skip. When finished, press Enter, then type reboot for changes to take effect. The
Current Values can only be saved and acted on after the IE-MiniFiberLinX-II has been
successfully rebooted.
Password Protection for Serial Port Connections
Password protection is provided for the serial configuration process by pressing P on
the main configuration screen. Enter a password, keeping in mind that passwords are
case-sensitive and must not exceed eight characters or include spaces, and press
Enter. This password will be requested whenever logging on. To remove password
protection, select P and, instead of entering a password, press Enter. If a password
becomes lost, contact IMC Networks Technical Support at (949) 465-3000 or (800)
624-1070.
Assigning Trap Destinations
Traps are sent by the manageable device to a management PC when a certain event
takes place. To enter a trap destination, press T. At the “Enter a New IP Address.”
prompt, enter the appropriate IP address and press Enter. Then, type the name of
the community string (that the destination device has been configured to accept) and
press Enter. This function enables ALL of the device traps. To individually activate
and deactivate traps, use iConfig for configuration. Supported traps include: Link
Down, Link Up, Cold Start, Warm Start and Authentication Failure.