¾ Hello Time (1-10): The time that controls when, the switch sends

out the BPDU packet to check RSTP status. Enter a value between

1 and 10.

¾ Forward Delay Time (4-30): the number of seconds a port waits

before changing from its Rapid Spanning Tree Protocol learning

and listening state to the forwarding state. Enter a value between 4

and 30.

Note

Follow this rule to configure the MAX Age, Hello Time, and Forward

Delay Time.

2 x (Forward Delay Time value -1) >= Max Age value >= 2 x (Hello

Time value +1)

RSTP System Configuration interface