beautypg.com

Ata6824 [preliminary, Thermal resistance, Operating range – Rainbow Electronics ATA6824 User Manual

Page 14: Noise and surge immunity

background image

14

4931C–AUTO–09/06

ATA6824 [Preliminary]

7.

Thermal Resistance

Parameters

Symbol

Value

Unit

Thermal resistance junction to heat slug

R

thjc

< 5

K/W

Thermal resistance junction to ambient when heat
slug is soldered to PCB

R

thja

25

K/W

8.

Operating Range

The operating conditions define the limits for functional operation and parametric characteristics of the device. Functionality outside these
limits is not implied unless otherwise stated explicitly.

Parameters

Symbol

Min

Max

Unit

Operating supply voltage

(1)

V

VBAT1

7

18

V

Operating supply voltage

(2)

V

VBAT2

6

< 7

V

Operating supply voltage

(3)

V

VBAT3

3

< 6

V

Operating supply voltage

(4)

V

VBAT4

0

< 3

V

Operating supply voltage

(5)

V

VBAT5

> 20

40

V

Junction temperature range under bias

T

j

–40

+200

°C

Normal functionality

T

a

–40

+150

°C

Normal functionality, overtemperature warning

T

a

180

200

°C

Drivers for H1, H2, L1, L2, and SIO are switched
OFF, VCC regulator is OFF

T

a

200

220

°C

Note:

1. Full functionality

2. H-bridge drivers may be switched off (undervoltage detection)

3. H-bridge drivers are switched off, 5V/3.3V regulator with reduced parameters, RESET works correctly

4. H-bridge drivers are switched off, 5V regulator not working, RESET not correct

5. H-bridge drivers are switched off

9.

Noise and Surge Immunity

Parameters

Test Conditions

Value

Conducted interferences

ISO 7637-1

Level 4

(1)

Interference suppression

VDE 0879 Part 2

Level 5

ESD (Human Body Model)

ESD S 5.1

2 kV

CDM (Charge Device Model)

ESD STM5.3.

500V

Note:

1. Test pulse 5: V

vbmax

= 40V