beautypg.com

Ata6824 [preliminary, 5 control inputs dir and pwm – Rainbow Electronics ATA6824 User Manual

Page 10

background image

10

4931C–AUTO–09/06

ATA6824 [Preliminary]

5.5

Control Inputs DIR and PWM

5.5.1

Pin DIR

Logical input to control the direction of the external motor to be controlled by the IC. An internal
pull-down resistor is included.

5.5.2

Pin PWM

Logical input for PWM information delivered by external microcontroller. Duty cycle and fre-
quency at this pin are passed through to the H-bridge. An internal pull-down resistor is included.

The internal signal ON is high when

• At least one valid trigger has been accepted (SYNC = 1)

• V

BAT

is inside the specified range (UV = 0 and nOV = 1)

• The charge pump has reached its minimum voltage (CPOK = 1) and

• The device is not overheated (OT2 = 0)

In case of a short circuit, the appropriate transistor is switched off after a debounce time of about
10 µs. In order to avoid cross current through the bridge, a cross conduction timer is imple-
mented. Its time constant is programmable by means of an RC combination.

Table 5-1.

Status of the IC Depending on Control Inputs and Detected Failures

Control Inputs

Driver Stage for External Power MOS

Comments

ON

DIR

PWM

H1

L1

H2

L2

0

X

X

OFF

OFF

OFF

OFF

Standby mode

1

0

PWM

ON

OFF

/PWM

PWM

Motor PWM forward

1

1

PWM

/PWM

PWM

ON

OFF

Motor PWM reverse

Table 5-2.

Status of the Diagnostic Outputs

Device Status

Diagnostic Outputs

Comments

CPOK

OT1

OV

UV

SC

DG1

DG2

DG3

0

X

X

X

X

1

Charge pump failure

X

1

X

X

X

1

Overtemperature warning

X

X

1

X

X

1

Overvoltage

X

X

X

1

X

1

Undervoltage

X

X

X

X

1

1

Short circuit

Note:

X represents: don't care – no effect)
OT1: Overtemperature warning
OV: Overvoltage of VBAT
UV: Undervoltage of VBAT
SC: Short circuit