8. TABLE OF OPERATING MODES
Fully synchronous operations are performed to latch the commands at the positive edges of CLK.
Table 1 shows the truth table for the operation commands.
TABLE 1 TRUTH TABLE (NOTE (1), (2))
COMMAND DEVICE
STATE
CKEN-1
CKEN
DQM
BS0, 1 A10 A0-A9
CS
RAS
CAS
WE
Bank Active
Idle
H
x
x
v
v
V
L
L
H
H
Bank
Precharge
Any H x x v L x L L H
L
Precharge All
Any
H
x
x
x
H
x
L
L
H
L
Write Active
(3)
H
x
x
v
L
v
L
H
L
L
Write with Autoprecharge
Active (3)
H
x
x
v
H
v
L
H
L
L
Read Active
(3)
H
x
x
v
L
v
L
H
L
H
Read with Autoprecharge
Active (3)
H
x
x
v
H
v
L
H
L
H
Mode Register Set
Idle
H
x
x
v
v
v
L
L
L
L
No-Operation Any
H
x
x
x
x
x
L
H
H
H
Burst Stop
Active (4)
H
x
x
x
x
x
L
H
H
L
Device Deselect
Any
H
x
x
x
x
x
H
x
x
x
Auto-Refresh Idle
H
H
x
x
x
x
L
L
L
H
Self-Refresh Entry
Idle
H
L
x
x
x
x
L
L
L
H
Self Refresh Exit
idle
(S.R)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
x
x
Clock suspend Mode Entry
Active
H
L
x
x
x
x
x
x
x
x
Power Down Mode Entry
Idle
Active (5)
H
H
L
L
x
x
x
x
x
x
x
x
H
L
x
H
x
H
X
H
Clock Suspend Mode Exit
Active
L
H
x
x
x
x
x
x
x
X
Power Down Mode Exit
Any
(power
down)
L
L
H
H
x
x
x
x
x
x
x
x
H
L
x
H
x
H
X
H
Data write/Output Enable
Active
H
x
L
x
x
x
x
x
x
x
Data Write/Output Disable
Active
H
x
H
x
x
x
x
x
x
x
Notes
:
(1) v = valid, x = Don’t care, L = Low Level, H = High Level
(2) CKEn signal is input leve l when commands are provided.