Rf12b, Ac characteristics (others), Ac characteristics (continued) – Rainbow Electronics RF12B User Manual
Page 11

RF12B
Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com
AC Characteristics (Others)
Symbol
Parameter
Conditions/Notes
Min Typ Max Units
C
xl
Crystal load capacitance,
see crystal selection guide
Programmable in 0.5 pF steps, tolerance
+/- 10%
8.5
16 pF
t
POR
Internal POR timeout
After Vdd has reached 90% of final value
(Note 9)
100 ms
t
PBt
Wake-up timer clock period
Calibrated every 30 seconds
0.95
1.05 ms
C
in, D
Digital input capacitance
2
pF
t
r, f
Digital output rise/fall time
15 pF pure capacitive load
10
ns
AC Characteristics (continued)
Note 1: Not using a 10 MHz crystal is allowed but not recommended because all crystal referred timing
and frequency parameters will change accordingly.
Note 2: See the BER diagrams in the measurement results section for detailed information.
Note 3: Measured with disabled clock output buffer. This current can be decreased by enabling the low
power mode of the crystal oscillator. See PLL Setting Command and Power Management Command for
details.
Note 4: See Reference design with 50 Ohm matching network for details.
Note 5: See Reference design with resonant PCB antenna (BIFA) for details.
Note 6: Supposing identical antenna with RF12B in RX mode, the outdoor RF link range will be
approximately 120 meters indoor and 450 meters outdoor.
Note 7: Optimal antenna admittance/impedance:
RF12B
Yantenna [S]
Zantenna [Ohm]
Lantenna [nH]
433 MHz 1.4E-3 - j7.1E-3
27 + j136
52.00
868 MHz 2E-3 - j1.5E-2
8.7 + j66
12.50
915 MHz 2.2E-3 - j1.55E-2
9 + j63
11.20
Note 8: Adjustable in 8 steps.
Note 9: During this period, commands are not accepted by the chip.