MAX5971B

Single-Port, 40W, IEEE 802.3af/at,

PSE Controller with I

2

C

Detect Event Register (R04h/R05h)

The detect event register (R04h/R05h, Table 10) records
detection/classification events for the port. On power-up
or after a reset condition, the detect event register is set
to a default value of 00h. DET_END and CL_END are
set high whenever detection/classification is completed.
As with the other event registers, the detect event reg-
ister has two addresses. When read through the R04h
address, the content of the register is left unchanged.
When read through the CoR R05h address, the register
content is reset to the default state.

Fault Event Register (R06h/R07h)

The fault event register (R06h/R07h, Table 11) records load
removal and overcurrent events for the port. On power-up
or after a reset condition, the fault event register is set to

a default value of 00h. LD_DISC is set to 1 whenever
the port shuts down due to detection of load removal.
IMAX_FLT is set to 1 when the port shuts down due to an
extended overcurrent event after a successful startup.
As with the other events registers, the fault event reg-
ister has two addresses. When read through the R06h
address, the content of the register is left unchanged.
When read through the CoR R07h address, the register
content is reset to the default state.

Reserved Registers (R08h/R09h)

Registers R08h/R09h are at this time reserved. Writing
to this register has no effect (the address autoincre-
ment still updates) and any attempt to read this register
returns all zeros.

Table 10. Detect Event Register

Table 11. Fault Event Register

ADDRESS =

04h

05h

DESCRIPTION

SYMBOL

BIT NO.

TYPE

R/W

Reserved

7

Reserved

Reserved

6

Reserved

Reserved

5

Reserved

CL_END

4

R

CoR

Classification completed on the port

Reserved

3

Reserved

Reserved

2

Reserved

Reserved

1

Reserved

DET_END

0

R

CoR

Detection completed on the port

ADDRESS =

06h

07h

DESCRIPTION

SYMBOL

BIT NO.

TYPE

TYPE

Reserved

7

Reserved

Reserved

6

Reserved

Reserved

5

Reserved

LD_DISC

4

R

CoR

Disconnect on the port

Reserved

3

Reserved

Reserved

2

Reserved

Reserved

1

Reserved

IMAX_FLT

0

R

CoR

Overcurrent on the port