Typical operating characteristics (continued) – Rainbow Electronics MAX19995 User Manual
Page 13

MAX19995
Dual, SiGe, High-Linearity, 1700MHz to 2200MHz
Downconversion Mixer with LO Buffer/Switch
______________________________________________________________________________________
13
Typical Operating Characteristics (continued)
(
Typical Application Circuit, optimized for the DCS/PCS band, R1 = R4 = 806
Ω, R2 = R5 = 2.32kΩ, V
CC
= +5.0V, P
LO
= 0dBm,
P
RF
= -5dBm, LO is low-side injected for a 190MHz IF, T
C
= +25°C, unless otherwise noted.)
CHANNEL ISOLATION vs. RF FREQUENCY
(VARIOUS VALUES OF L3 AND L6)
MAX19995 toc46
RF FREQUENCY (MHz)
CHANNEL ISOLATION (dB)
2500
1900
2100
2300
45
55
50
60
30
35
40
1700
0
Ω
10nH
6.8nH
3.6nH
LO LEAKAGE AT IF PORT vs. LO FREQUENCY
(VARIOUS VALUES OF L3 AND L6)
MAX19995 toc47
LO FREQUENCY (MHz)
LO LEAKAGE AT IF PORT (dBm)
2300
1700
1900
2100
-40
-30
-20
-60
-50
1500
0
Ω
10nH
6.8nH
3.6nH
RF-TO-IF ISOLATION vs. RF FREQUENCY
(VARIOUS VALUES OF L3 AND L6)
MAX19995 toc48
RF FREQUENCY (MHz)
RF-TO-IF ISOLATION (dB)
2500
1900
2100
2300
40
50
60
20
30
1700
0
Ω
10nH
6.8nH
3.6nH