beautypg.com

Introduction – Cobalt Digital COMPASS 9284 3G_HD_SD-SDI 8X4 Video Routing Switch User Manual

Page 25

background image

9284-OM (V1.3)

9284 PRODUCT MANUAL

1-21

Introduction

9284 Functional Description

“T”: Trigger a Salvo Connect Sequence

The command “T” is used to trigger a previously set up salvo (set using the
“P” command above). It must be followed by a register letter from A to Z or a
register number from 1 to 256 giving the register to be triggered.

For example, the command:

** TB D180 TC !!

says to trigger salvo register B (same as 2), delay 180 sync intervals, then
trigger salvo register C (same as 3). When the register is triggered, this means
that the connect commands stored in it take effect.

If a salvo is triggered and it attempts to connect a locked output or port, or a
disallowed input/output pair, or a port to itself, the salvo trigger operation is
aborted, no crosspoint changes are performed, and an error is reported:
“ERROR Salvo Has Locked Xpts”.

From Syntax

Description

Host

T reg

Trigger a list of connect commands
stored in a salvo register.

Router

(None)