Click mode – Snap-On Motorized Loader User Manual
Page 85

6-13
2000-800-02 Motorized Loader
1. In case of an emergency, push E-STOP (Emergency
STOP) to shut down the motor.
2. Push System Control OFF (Red) button to suspend
system operations. Push System Control ON (Green)
button to resume system operations.
3. In case of a system error, use hand crank to release
wrench.
Click Mode:
( This mode is used to check or test the Click wrenches ).
· Setup the Torque Tester:
** Mode: First Peak
** Select an appropriate Unit (ft-lb, Nm, etc.)
· Setup Motorized Control Box:
** Press
F1
to select Click Mode.
The LCD display reads:
Press
Run
to start Click Mode.
The LCD display reads:
Use cursor keys Up, Down, Left, Right to enter
Target value, Number of Cycles and Direction.
Example:
For Click Wrench setting of 50 ft-lb, set Target Value at 50 ft-lb.
Press RUN or Enter key to accept all Parameters.
NOTE:
The default Setup upon Power Up is:
* Target :
7% of Transducer.
* Cycle:
00001
* Dir:
CW
The MCB does NOT accept any Target Value that exceeds
the Maximum Transducer Range.
MODE (Click)
Press Run to Start
*** CLICK MODE ***
Target Cycle Dir
50.00 ft.lb 00005 CW