beautypg.com

Universal stiffener seal kit, Rega – Grain Systems Tanks PNEG-2400 User Manual

Page 83

background image

9. Aeration Transition Instructions

PNEG-2400 CFL Commercial Farm 4" Corrugation Externally Stiffened Grain Bin

83

Universal Stiffener Seal Kit

Seal Kit (TR-7067) (Optional)

Air deflector included in seal kit (TR-7067) may be installed over stiffener at customer’s request.

An access hole must be cut for the stiffener in bottom of the transition housing. Cut a 9" x 6" hole in the
bottom center of the transition before attaching the transition to the bin. Attach transition to sidewall sheet
as shown in

Figure 9E

. Field drill 3/8" stiffener holes through transition entrance collar. A hole must now

be cut in the top center of the transition. Mark a 9" wide x 6" opening for the stiffener to enter. Cut along
the line. Bottom edge of entrance collar will also need to be trimmed to provide clear access for stiffener.

Place stiffener through transition housing and attach to sidewall. Be sure stiffener anchor is located on
anchor bolt. Place washer and nut on anchor bolt and tighten.

Stiffener transition cover plates are supplied to seal stiffener to the transition housing. Caulk one side of
cover plate on the three (3) straight edges. Place stiffener transition cover plate on top of transition housing
and use the self-drilling screws to fasten cover plate to transition. Repeat this procedure on the inside
bottom of the transition housing. The cover plates will need to be trimmed to fit properly on the bottom.
Caulk and seal everything well when plates have been secured.

Figure 9E