5. Wind Ring Assembly Instructions

Wind Ring Assembly

Figure 5A

1. To connect wind ring pipe to the stiffeners, attach with 3/8" x 1" bolts through the flange of the

stiffener. Field drilling of wind ring locations may be required in some cases.

2. Attach wind ring pipe section to stiffener using two (2) 3/8" x 6" (S-7248) wind ring clamps.

3. Place pipes end to end without overlapping. Fasten together using two (2) wind ring couplers

and six (6) 3/8" x 1" flanged head bolts with flanged nuts. Couplers should be centered on the
seam of pipes.