4. Assembly

18

PNEG-1049 10"-12" Commercial Bin Sweep Augers

8. Place the 2" O.D. x 11-1/2" connecting shaft into the free end of the flight. Once the holes are aligned

properly, attach the shaft to the flight using two (2) 5/8" x 4" grade 8 hex bolts and stover nuts.

(See Figure 4H.)

Figure 4H Connecting Shaft to Flight

9. Place the bearing stand assembly onto the connecting shaft.

(See Figure 4I.)