8. Vision/Dri-Tek Dryer Operation
38
PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual
Figure 8B
14. Set the plenums 15°C to 30°C apart. Warmest at the top.
15. DO NOT ADJUST THE DRYER FOR MOISTURE DURING THIS PROCESS. THIS WILL CAUSE
CONTROL INSTABILITY.
16. After the run time in
, set the moisture control. Unload switch = AUTO.
17. Push the meter roll adjustment knob. Ensure 2 Speed is selected.
18. Set the high and low speeds according to the drying chart. Toggle between speed settings by
pressing the adjustment knob. Press ACCEPT.
Figure 8C
19. Moisture control is now active.
20. Set the temperature set point. M/C > Set Temperature Set Point 40°C > ACCEPT. Run on these
settings as a starting point before adjusting moisture or meter roll settings. Moisture control will not
be precise at this stage.
- PNEG-1890 (16 pages)
- PNEG-595 (26 pages)
- PNEG-1472 (30 pages)
- PNEG-897 (58 pages)
- PNEG-838 (4 pages)
- PNEG-1755 (36 pages)
- PNEG-524 (24 pages)
- PNEG-1080 (2 pages)
- PNEG-728 (47 pages)
- PNEG-673 (57 pages)
- PNEG-823 (42 pages)
- PNEG-630-6S (23 pages)
- PNEG-1876 (80 pages)
- PNEG-102 (2 pages)
- PNEG-366 (51 pages)
- PNEG-1626 (1 page)
- PNEG-1874 (78 pages)
- PNEG-1798 (34 pages)
- PNEG-1927 (4 pages)
- PNEG-924 (2 pages)
- PNEG-582 (26 pages)
- PNEG-012 (46 pages)
- PNEG-1797 (86 pages)
- PNEG-546 (26 pages)
- PNEG-951 (102 pages)
- PNEG-1650 (92 pages)
- PNEG-1649 (50 pages)
- PNEG-1376 (88 pages)
- PNEG-361 (46 pages)
- PNEG-338 (32 pages)
- PNEG-1276 (78 pages)
- PNEG-1283 (22 pages)
- PNEG-1089 (14 pages)
- QSG-001 (2 pages)
- PNEG-950 (96 pages)
- PNEG-1590 (3 pages)
- PNEG-501 (33 pages)
- PNEG-1447 (68 pages)
- PNEG-707GSI (446 pages)
- PNEG-349 (32 pages)
- PNEG-236 (22 pages)
- PNEG-743 (16 pages)
- PNEG-900 (54 pages)
- PNEG-1935 (92 pages)