Adjustment elements
4 keys
Protection rating
-
unassembled
IP
20
-
mounted into the sensor without cover
IP
40
Materials
-
Housing
ABS
-
Inspection window
Polyester foil
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone Ex factory
CET
Measurement electronics temerature
Resolution
1 °C (1.8 °F)
Accuracy
±1 °C
(1.8 °F)
Voltage supply
Operating voltage
-
Non-Ex instrument
9 … 32 V DC
-
Non-Ex instrument
9 … 32 V DC
-
EEx-ia instrument - Power supply FISCO
model
9 … 17.5 V DC
-
EEx-ia instrument - Power supply EN-
TITY model
9 … 24 V DC
-
EEx-d instrument
14 … 32 V DC
Power supply by/max. number of sensors
-
H
1 power supply
max. 32 (max. 10 with Ex)
Electrical protective measures
Protection, depending on housing version
-
Plastic housing
IP
66/IP 67
-
Aluminium housing, stainless steel
housing - investment casting, stainless
steel housing - electro-polished
IP
66/IP 68 (0.2 bar)
8)
-
Aluminium and stainless housing, in-
vestment casting (optionally available)
IP
66/IP 68 (1 bar)
Overvoltage category
III
8)
The prerequisites for maintaining the protection rating are a suitable cable
as well as correct mounting.