VEGA VEGAPULS 61 (≥ 2.0.0 - ≥ 4.0.0) Foundation Fieldbus Approval according to LPR radio standard User Manual
Page 37
Enter the requested parameters via the appropriate keys, save your
settings with [OK] and jump to the next menu item with the [ESC] and
the [->] key.
In addition to the medium, also the application, i.e. the measuring site,
can influence the measurement.
With this menu item, the sensor can be adapted to the applications.
The adjustment possibilities depend on the selection "Liquid" or "Bulk
solid" under "Medium".
The following options are available when "Liquid" is selected:
The selection "Standpipe" opens a new window in which the inner
diameter of the applied standpipe is entered.
The following features form the basis of the applications:
Storage tank:
l
Setup: large-volumed, upright cylindrical, spherical
l
Product speed: slow filling and emptying
l
Process/measurement conditions:
-
Condensation
-
Smooth product surface
-
Max. requirement to the measurement accuracy
Storage tanke with product circulation:
l
Setup: large-volumed, upright cylindrical, spherical
l
Product speed: slow filling and emptying
l
Vessel: small laterally mounted or large top mounted stirrer
l
Process/measurement conditions:
-
Relatively smooth product surface
-
Max. requirement to the measurement accuracy
Setup/Application
VEGAPULS
61 • Approval according to LPR radio standard
37
6 Set up with the indicating and adjustment module
41716
-EN
-120301