VEGASCAN 850

73

Setup - Adjustment with the PC

In the illustration, you see the echo curve
(before correction of the sensor orientation)
with a false echo nearly as large as the prod-
uct echo.

In the next illustration you then see the echo
curve after optimum directing of the sensor to
the product surface and away from a large
false echo source (sensor axis perpendicular
to the product surface). The false echo,
caused e.g. by a strut, is now reduced by
more than 30 dB and will no longer influence
the measurement.

• Quit the menu "

Echo curve“ with

"Quit“.

False echo storage

With the menu item "

False echo storage“ in

the menu "

Sensor optimisation“ you can au-

thorise the sensor to save false echoes. The
sensor electronics then saves the false ech-
oes in an internal database and assigns them
a lower level of importance than the useful
echo. The false echo storage should be car-
ried out with empty vessel.

• Click in the menu window "

Sensor optimisa-

tion“ to the menu item

"False echo storage“.