beautypg.com

VEGA VEGASCAN 850 User Manual

Page 24

background image

24

VEGASCAN 850

Technical data

Materials

Housing

PBT (Valox) or Aluminium

Process fitting

- VEGASON 51, 52

PVDF (thread)

- VEGASON 53

PP or 1.4571 (compression flange)
1.43019 (mounting strap)

- VEGASON 54 … 56

- Alu or PP (version A)
- swivelling holder or thread G 1 A of

galvanized steel (version B, C and D)

Transducer

- VEGASON 51, 52

PVDF

- VEGASON 53

UP

- VEGASON 54

PA (1.4301 with StEx)

- VEGASON 55, 56

UP

Transducer diaphragm

- VEGASON 51, 52

PVDF

- VEGASON 53

1.4571

- VEGASON 54

1.4571

- VEGASON 55

Alu/PE foam

- VEGASON 56

Alu/PTFE coating

Transducer cable (cable cover)

- VEGASON 54, 55

PUR (1.1082)

- VEGASON 56

Silicone (1.1083)

Weight

VEGASON 51

1.2 kg

VEGASON 52

1.6 kg

VEGASON 53

2.3 kg

VEGASON 54

- version A

5.6 … 10.7 kg

- version B

6.9 … 9.7 kg

- version C

7.5 … 10.5 kg

- version D

4.7 … 6.9 kg

VEGASON 55

- version A

8.0 … 13.3 kg

- version B

8.7 … 10.3 kg

- version C

9.2 … 11.1 kg

- version D

6.5 … 7.5 kg

VEGASON 56

- version A

7.3 … 11.3 kg

- version B

8.7 … 10.3 kg

- version C

9.3 … 11.1 kg

- version D

6.5 … 7.5 kg

CE conformity

VEGASON series 50 ultrasonic sensors and VEGASCAN 850 meet the protective regula-
tions of EMC (89/336/EWG) and NSR (73/23/EWG). Conformity was judged acc. to the
following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993
EN 61 326 - 1: 1997/A1:1998