VEGA VEGASCAN 850 User Manual
Page 24
24
VEGASCAN 850
Technical data
Materials
Housing
PBT (Valox) or Aluminium
Process fitting
- VEGASON 51, 52
PVDF (thread)
- VEGASON 53
PP or 1.4571 (compression flange)
1.43019 (mounting strap)
- VEGASON 54 … 56
- Alu or PP (version A)
- swivelling holder or thread G 1 A of
galvanized steel (version B, C and D)
Transducer
- VEGASON 51, 52
PVDF
- VEGASON 53
UP
- VEGASON 54
PA (1.4301 with StEx)
- VEGASON 55, 56
UP
Transducer diaphragm
- VEGASON 51, 52
PVDF
- VEGASON 53
1.4571
- VEGASON 54
1.4571
- VEGASON 55
Alu/PE foam
- VEGASON 56
Alu/PTFE coating
Transducer cable (cable cover)
- VEGASON 54, 55
PUR (1.1082)
- VEGASON 56
Silicone (1.1083)
Weight
VEGASON 51
1.2 kg
VEGASON 52
1.6 kg
VEGASON 53
2.3 kg
VEGASON 54
- version A
5.6 … 10.7 kg
- version B
6.9 … 9.7 kg
- version C
7.5 … 10.5 kg
- version D
4.7 … 6.9 kg
VEGASON 55
- version A
8.0 … 13.3 kg
- version B
8.7 … 10.3 kg
- version C
9.2 … 11.1 kg
- version D
6.5 … 7.5 kg
VEGASON 56
- version A
7.3 … 11.3 kg
- version B
8.7 … 10.3 kg
- version C
9.3 … 11.1 kg
- version D
6.5 … 7.5 kg
CE conformity
VEGASON series 50 ultrasonic sensors and VEGASCAN 850 meet the protective regula-
tions of EMC (89/336/EWG) and NSR (73/23/EWG). Conformity was judged acc. to the
following standards:
EMC
Emission
EN 50 081 - 1: 1992
Susceptibility
EN 50 082 - 2: 1995
NSR
EN 61 010 - 1: 1993
EN 61 326 - 1: 1997/A1:1998