beautypg.com

6 flow measurement, Rectangular flume, Khafagi-venturi flume – VEGA VEGASCAN 850 User Manual

Page 46

background image

46

VEGASCAN 850

Mounting and installation

B

Khafagi-Venturi flume

90°

h

max

Sensor

3 … 4 x h

max

Flow measurement on open flumes

h

max

³ 2 x h

max

Overfall edge

90°

Flow measurement on open flumes

Upstream water

Downstream water

³ 5 cm

90°

3 … 4 x h

max

Overfall edge

³ max.
distance

4.6 Flow measurement

The short examples on this page are only
basic information on flow measurement. You
can get complete planning information from
the flume manufacturers and in special litera-
ture.

Rectangular flume

- Installation of the sensor on the upstream

side

- Note distance to the overfall edge

(3 … 4 x h

max

)

- Installation centered to the flume
- Edge opening

³ 2 x h

max

from ground

- Installation perpendicular to the liquid sur-

face

- Keep min. distance in relation to h

max

- Min. distance from edge opening to down-

stream water

³ 50 mm

Khafagi-Venturi flume

- Installation of the sensor on the inlet side
- Note distance to the Khafagi-Venturi flume

(3 … 4 x h

max

)

- Installation perpendicular to the liquid sur-

face

- Keep min. distance in relation to the height

of damming h

max