Technical data

Measuring range
(reference plane is the transducer end. On VEGASON 54 … 56 in version A the lower flange
side is the reference plane.)

VEGASON 51

- liquids

0.25 … 4 m

- solids

0.3 … 2 m

VEGASON 52

- liquids

0.4 … 7 m

- solids

0.5 … 3.5 m

VEGASON 53

- liquids

0.6 … 15 m

- solids

0.75 … 7 m

VEGASON 54 in general

1.0 … 25 m

VEGASON 55 in general

0.8 … 45 m

VEGASON 56

- version A

1.8 … 70 m

- version B … D

1.4 … 70 m

Output signal of the sensors

Signal output of the sensors

digital output signal in two-wire technology
(VBUS): the digital output signal (meas.
signal) is superimposed power supply of
VEGASCAN and further processed in
VEGASCAN

Meas. data inputs on VEGASCAN

Number of inputs

3 meas. data inputs on VEGASCAN 850B
6 meas. data inputs on VEGASCAN 850C

Supply voltage from VEGASCAN

approx. 24 V

Output current per meas. data input

max. 1 A

Output power

per meas. data input

max. 23 W (15 W continuous power)

Resistance of the signal cable

max. 15 W per wire or
max. 1000 m cable length

Integration time

0 … 999 seconds (selectable in the sensor)
0 … 600 seconds (selectable in VEGASCAN)

Two-wire technology: The digital output signal (meas. signal) and the power supply are led