VEGA VEGASON 71 - 1 … 75 - 1 User Manual
Page 7
Technical Information
71 - 1 … 75 - 1
7
Technical data
(continuation)
Current outputs
module
-
with
2 outputs
-
range
0/4 … 20 mA
-
resolution
0,05 % of range
-
load
max. 500 Ohm
-
load dependent
failure
at 0 … 500 Ohm, < 0,2 % related to the range
or
module
as above
however with 2 floating outputs each
Fail safe function
1 fail safe relay
1 spdt floating
contact data
as described under relay outputs
2 fail safe-LEDs
Ambient
ambient temperature on
conditions
-
transducer 71 … 75
–20
°
C … +80
°
C / -4 … 176
°
F
-
transducer 71 R … 73 R
–20
°
C … +55
°
C / -4 … 131
°
F
-
central electronics
–20
°
C … +60
°
C / -4 … 140
°
F
storage and transport temperature –20
°
C … +80
°
C / -4 … 176
°
F
Environmental
protection
protection
-
transducer 71 … 75
IP 68
-
transducer 71 R … 73 R
IP 68
-
housing of central electronics
IP 65
protection class
II
Electrical
terminals
for max. 1 x 1,5 mm
2
connections
cable entry
1 x Pg 7
1 x Pg 13,5, max. 5 x Pg 13,5
Material
transducer
PVDF
housing of central electronics
Polycarbonate
Weight
VEGASON
71 … 73
74 and 75
1 transducer (without cable)
approx. 0,8 kg
approx. 1,5 kg
central electronics
approx. 1,9 kg
approx. 1,9 kg
Dimensions
see dimensional drawing on following page