VEGA VEGASON 71 - 1 … 75 - 1 User Manual
Page 17
Start-up
71 - 1 … 75 - 1
17
Mode listing 0
general parameters
Relay
0 - 43
Coordination
output 1
- measuring result ....................................
in m =
1
in % =
2
p. 28
0 - 44
Mode
- two-point level switch .............................
1
- pump function switch ..............................
2
- tendency determination raising ..............
3
- tendency determination lowering ...........
4
0 - 45
Switching
1 (on) .............................
sensor specific
0 - 46
command
2 (off) .............................
sensor specific
0 - 47
Indication of running period .......................
indication in 10 h-units
Relay
0 - 48
Coordination
output 2
- measuring result .....................................
in m =
1
in % =
2
p. 28
0 - 49
Mode
- two-point level switch .............................
1
- pump function switch ..............................
2
- tendency determination raising ..............
3
- tendency determination lowering ...........
4
0 - 50
Switching
1 (on) .............................
sensor specific
0 - 51
command
2 (off) .............................
sensor specific
0 - 52
Indication of running period .......................
indication in 10 h-units
Relay
0 - 53
Coordination
output 3
- measuring result .....................................
in m =
1
in % =
2
p. 28
0 - 54
Mode
- two-point level switch .............................
1
- pump function switch ..............................
2
- tendency determination raising .............
3
- tendency determination lowering ...........
4
0 - 55
Switching
1 (on) .............................
sensor specific
0 - 56
command
2 (off) .............................
sensor specific
0 - 57
Indication of running period .......................
indication in 10 h-units
Relay
0 - 58
Coordination
output 4
- measuring result .....................................
in m =
1
in % =
2
p. 28
0 - 59
Mode
- two-point level switch ..............................
1
- pump function switch ..............................
2
- tendency determination raising ..............
3
- tendency determination lowering ...........
4
0 - 60
Switching
1 (on) .............................
sensor specific
0 - 61
command
2 (off) .............................
sensor specific
0 - 62
Indication of running period .......................
indication in 10 h-units
0 - 63
Interval time for pump function ..................
0000
…
9999
p. 31
Function
Mode-no.
Mode description
Parameter
Page
(
= factory preset)
(continuation)