50
71 - 1 … 75 - 1
Mode-no.
Mode description
Factory preset
Sensor optimization
1
2
3
Working range
1 - 07
-
start .......................................................
0.00 m
1 - 08
-
end
71 - 1 ...................................
6.00 m
72 - 1 ...................................
12.00 m
73 - 1 ...................................
12.00 m
74 - 1 ...................................
24.00 m
75 - 1 ...................................
36.00 m
Product type
1 - 09
-
liquid / solid
for VEGASON 72 ..................................
1 (liquid)
for VEGASON 73 … 75 ........................
0 (solid)
Solid
1 - 10
-
angle of repose in degrees ...................
0 degrees
1 - 11
-
particle size ...........................................
11 mm
Liquid
1 - 10
-
vessel top flat / dished ..........................
1 (flat)
Multiple false echo
1 - 12
-
reduction in Volt ....................................
0.00
1 - 13
-
optimization............................................
0.00
False echo learn
1 - 15
-
learn distance in m ................................
2.00
1 - 16
-
delete learn cycle ..................................
0 (off)
1 - 17
-
activate learn cycle ...............................
0 (off)
1 - 18
Profile interpolation ....................................
0 (off)
1 - 19
Rate of product level change in cm / sec. ..
4.00
Max. gain
1 - 21
-
limitation in Volt .....................................
0.03
1 - 22
-
optimization in Volt ................................
0.03
1 - 23
Measuring window .....................................
1 (on)
1 - 24
Fault signal ................................................
0 (off)
1 - 25
Real distance in m .....................................
2.00
1 - 27
Basic adjustment .......................................
0 (off)
Date
Name
Protocol of the sensor optimization