VEGA VEGASON 71 - 1 … 75 - 1 User Manual
Page 23
Linearization
71 - 1 … 75 - 1
23
Determination of the index markers
Gauging the level in litres
-
mode 40: coordinate display 1 to level 1
-
mode 99: select linearization curve 4
-
fill or empty step by step with part volume
-
note the respectively measured values for H %
(level percentage) or display 1 on the linearity
protocol
-
the respective value for L % (volume percent-
age) should be calculated as follows
100 % x part volume 1 (…32)
L % = ––––––––––––––––––––––––
vessel volume
e.g. volume percentage for 1 part volume:
100 % x 5 m
3
L % = –––––––––––– = 5 % (acc. to example)
100 m
3
-
note the calculated values for L % in the linearity
protocol
-
continue the procedure of "gauging the level in
litres" with the same part volume until H 100 %
and L 100 % as described above.
-
Attention:
The linearization curves must ALWAYS be
finished with H 100 % and L 100 %. This finish
can be programmed after any number of index
markers.
Demonstration
to the following programming example (see page 24)
Heights %
Volu-
me
%
5
etc.
level perc. 02
level perc. 01
0
30
40
50
70
80
60
90
100
10
20
30
40
50
60
70
80
90
100
20
10
100.0
12.0
4.H.01
4.L.01
4.L.32
5.0
100.0
4H.32
index marker
01 … 32
index marker
01 … 32