Start-up
18
71 - 1 … 75 - 1
Mode listing 0
general parameters
Function
Mode-no.
Mode description
Parameter
Page
(
= factory preset)
(continuation)
Current
0 - 64
not used .....................................................
– – – –
output
0 - 65
Charac-
- end ...............................
20.00
…
00.00
p. 34
1 and 2
0 - 66
teristics
- start ..............................
00.00
…
04.00
…
20.00
0 - 67
…
92
not used .....................................................
– – – –
0 - 93
Fault signal processing
store actual current
switching relay
unchanged
=
1
current 0 mA
switching relay
de-energizes
=
2
current goes to 0 %
p. 35
switching relay
de-energizes
=
3
current goes to 100 %
switching relay
de-energizes
=
4
0 - 94
Simulation .................................................
sensor specific in m
p. 36
0 - 95
…
96
not used ....................................................
– – – –
0 - 97
Basic
- switched off ..................
0
p. 37
adjustment
- switched on ..................
1
0 - 98
Keyword
- switched off ..................
0
p. 37
(=
0070
)
- switched on ..................
1
0 - 99
Change
-
general parameter ................
0
-
sensor optimization ..............
1
-
not used ...............................
2
p. 38
-
linearization curve 4 .............
4
-
linearization curve 5 .............
5
-
linearization curve 6 .............
6