EnvironmEntal SEnSorS
inStallation GUiDE
Digital Pressure/Vacuum Gauge with Display
and Analog 4-20 mA Output
quick install
1. Select a location for the installation suitable to the gauge’s physical dimensions
that will allow access to the display and keypad. Plan for a ¼" M-NPT connection
or a hose to a ¼" fitting.
2. Thread the gauge onto the fitting. Apply tightening torque only to the metal
wrench flats, not to the PD housing. Use a 5/8” wrench. Do not overtighten.
3. Wire the device. See the wiring diagram in this guide.
4. Remove the protective film from the gauge front.
5. Program the gauge.
Installer’s Specifications
Measurement Units
Selectable: psi, bar, kg/cm2, ATM, in. Hg, in. H
2
O*
Accuracy**
< ±0.5% of F.S., BFLS
Overange Protection
2x rated pressure
Burst Pressure
5x rated pressure or 5000 psi, whichever is less
Temperature Ranges:
Operating (Ambient)
-10° to 70°C (15° to 158°F)
Storage
-40° to 65°C (-40° to 150°F)
Thermal Limits:
Compensated Range
0° to 55°C (32° to 131°F)
TC Zero
< ±1.5% of F.S.
TC Span
< ±1.5% of F.S.
Connection
¼" NPT, male
Power***
7.5 to 32 VDC
Housing
Polycarbonate
Environmental Protection
NEMA 4, IP65
Output
4-20 mA loop powered
* in. H2O units available on ≤250 psi range devices only
** Accuracy includes non-linearity, hysteresis and non-repeatability measured at 25°C/77°F
*** Select a loop power supply and total loop resistance such that when the loop current is 20 mA,
the gauge will have at least 7.5 VDC at its terminals.
PD SerieS
PD SerieS
Dimensions
NOTICE
• This product is not intended for life or safety applications.
• Do not install this product in hazardous or classified locations.
• Read and understand the instructions before installing
this product.
• Turn off all power supplying equipment before working on it.
• The installer is responsible for conformance to all applicable codes.
Range
= 17 - 4 SS
Output
= 4-20 mA
Material
50 = 0 to 50 psig
100 = 0 to 100 psig
250 = 0 to 250 psig
500 = 0 to 500 psig
1000 = 0 to 1000 psig
PD A
M
ProDuct iDentification
Zero
VERIS INDUSTRIES
http://www.veris.com
1-800-354-8556
1-503-598-4564
Digital Pressure Gauge
3.6”
(90mm)
4.2”
(106mm)
Calib
2.8”
(72mm)
1.8”
(46mm)
1.4”
(36mm)
2.2”
(56mm)
0.7”
(17mm)
Test Units
5/8”
Front
Side
Rear
Wrench Flat