8.3
Pre Configuration File rules
The framework of the text file follows strictly defined rules.
The main framework is divided in two parts:
1. An instruction section is used to drive a generic data creation for
those fields, not filled within data sequence section.
2. A data sequence section defines data record fields. Each of them
are explicitly set
Layout rules in detail are:
• Comments start with “#”
• Each record is terminated by the regular expressions “\r” or “\n”
• Instruction settings are made like:
• Data sequence sections starts with the key word “data_sequence”.
This key word is always mandatory to proceed the file. All
instructions have to be written before this row.
• Data sequence record fields are separated by colon “;”. Colons have
also to be set for empty fields, if at least one follows which is not
empty. Otherwise a position mismatch of fields will occur.
• If fields have several values assigned (that may be true for a few local
RFP configuration fields like ntp_address), they must be separated by
comma “,”.
Notes:
• Because of data sequence fields are separated by colon the content of
that section can possibly be generated by a .csv export of Excel-Sheet
and copied into the configuration file.
• Instructions are only proceeded on those fields, which are left empty
within the data sequence section