beautypg.com

2 reset to the factory defaults – ZyXEL Communications ES-3124PWR User Manual

Page 54

background image

Dimension ES-3124PWR Ethernet Switch

4-8

Introducing the Web Configurator

Figure 4-4 Reload the Configuration file: Via Console Port

The switch is now reinitialized with a default configuration file including the default password of “1234”.

4.5.2

Reset to the Factory Defaults

To reset the switch back to the factory defaults, do the following:

Step 1.

Connect to the console port using a computer with terminal emulation software. See the chapter on
hardware connections for details.

Step 2.

Disconnect and reconnect the switch’s power to begin a session. When you reconnect the switch’s power,
you will see the initial screen.

Step 3.

When you see the message “Press any key to enter Debug Mode within 3 seconds”
press any key to enter debug mode.

Step 4.

Type atbr after the “Enter Debug Mode” message.

Figure 4-5 Reset the Switch: Via Console Port

Step 5.

After the resetting, type atgo to restart the switch.

Bootbase Version: V0.1 | 02/01/2005 16:33:32

RAM:Size = 32 Mbytes

DRAM POST: Testing: 32768K OK

DRAM Test SUCCESS !

FLASH: Intel 32M

ZyNOS Version: V3.60(TY.0)b1.1 | 04/15/2005 17:08:38

Press any key to enter debug mode within 3 seconds.

..................

Enter Debug Mode

ES-3124PWR> atlc

Starting XMODEM upload (CRC mode)....

CCCC

Total 393216 bytes received.

Erasing...

...........................................................................

.....OK

ES-3124PWR> atgo

Bootbase Version: V0.1 | 02/01/2005 16:33:32

RAM:Size = 32 Mbytes

DRAM POST: Testing: 32768K OK

DRAM Test SUCCESS !

FLASH: Intel 32M

ZyNOS Version: V3.60(TY.0)b1.1 | 04/15/2005 17:08:38

Press any key to enter debug mode within 3 seconds.

................

Enter Debug Mode

ES-3124PWR> atbr

Restore default

Romfile.........................................................

..........OK

ES-3124PWR> atgo