beautypg.com

York H*RD018 THRU 060 User Manual

Page 23

background image

254892-YTG-C-0606

Unitary Products Group

23

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

*

= Single-phase outdoor units only.

*

= Single-phase outdoor units only.

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

H2RD060S06, H1RD060S(25,46)**

INDOOR COIL MODEL NO.

FC/MC/PC/UC60

CONDENSING

ENTERING AIR

TEMPERATURE

IDCFM

1650

1900

2150

ID

DB

(°F)

80 80

75

80

80

80 80 75

80

80 80 80

75 80 80

ID

WB

(°F)

57 62 62 67 72 57 62 62 67 72 57 62 62 67 72

65

T.C.

57.2 57.4 54.0 59.6 59.1 58.9 59.1 55.2 60.4 61.1 60.6 60.8 56.3 61.2 63.1

S.C.

52.1 48.7 39.6 38.8 28.1 54.1 51.9 42.7 42.0 31.1 56.1 55.2 45.7 45.3 34.1

KW

3.0 3.1 3.1 3.1 3.1 3.0 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1

75

T.C.

54.9 55.1 51.6 57.2 57.0 56.9 56.8 52.7 58.1 58.2 59.0 58.5 53.8 59.0 59.5

S.C.

50.0 47.4 38.6 38.0 27.7 52.1 50.5 41.6 41.1 30.0 54.2 53.6 44.7 44.2 32.3

KW

3.5 3.5 3.5 3.6 3.6 3.5 3.5 3.5 3.6 3.6 3.5 3.5 3.5 3.6 3.6

85

T.C.

52.6 52.9 49.3 54.8 54.8 54.9 54.5 50.3 55.8 55.4 57.3 56.1 51.2 56.9 55.9

S.C.

48.0 46.1 37.6 37.3 27.3 50.1 49.0 40.6 40.2 28.8 52.3 52.0 43.6 43.2 30.4

KW

4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 4.0 4.1

95

T.C.

50.2 50.7 46.9 52.4 52.7 52.9 52.2 47.8 55.0 52.5 55.6 53.7 48.7 54.7 52.3

S.C.

45.9 44.8 36.5 36.5 26.9 48.1 47.6 39.5 39.6 27.7 50.4 50.4 42.5 42.1 28.5

KW

4.4 4.4 4.4 4.4 4.6 4.5 4.4 4.4 4.5 4.6 4.5 4.4 4.4 4.5 4.6

105

T.C.

48.3 48.2 44.9 49.9 49.4 50.5 49.9 45.3 50.8 49.2 52.8 51.6 45.6 51.6 49.0

S.C.

43.9 43.2 35.6 35.4 25.7 46.0 45.6 38.4 38.1 26.8 48.0 47.9 41.1 40.8 28.0

KW

5.1 5.0 5.1 5.1 5.2 5.1 5.1 5.1 5.1 5.2 5.1 5.1 5.1 5.1 5.2

115

T.C.

46.4 45.9 43.0 47.5 46.1 48.2 47.7 42.8 48.1 46.0 50.0 49.6 42.5 48.6 45.9

S.C.

42.0 41.7 34.7 34.4 24.6 43.9 43.6 37.2 37.0 26.0 45.7 45.5 39.8 39.5 27.5

KW

5.7 5.7 5.7 5.7 5.8 5.7 5.7 5.7 5.7 5.8 5.7 5.7 5.7 5.7 5.8

125

T.C.

44.5 43.5 41.1 45.1 42.9 45.8 45.5 40.3 45.3 42.8 47.2 47.6 39.5 45.6 42.7

S.C.

40.1 40.2 33.7 33.4 23.5 41.8 41.6 36.1 35.8 25.2 43.4 43.1 38.4 38.3 26.9

KW

6.3 6.3 6.3 6.3 6.4 6.3 6.3 6.3 6.3 6.5 6.3 6.4 6.3 6.3 6.5

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
**

For three-phase, decrease T.C. by 0.5 and S.C. by 0.3.

Air Handler

Coil

T.C.

S.C.

KW

MA20D

MC60D

1.00 1.00 1.00

MA20D

MC61D

1.01 1.01 1.01

MA20D

G*FD060H24

1.00 1.00 1.00

MA20D

G*FD061H24

1.01 1.01 1.01

AHP/SHP60

1.00 1.02 1.00

F*FV060*

1.00 1.02 1.00

MV20D*

FC/MC60D

0.98 0.97 0.98

MV20D*

MC61D

1.01 0.99 1.01

AV/SV60*

1.00 1.02 1.00

MC61

1.01 1.01 1.01

HC60

1.00 1.00 1.00

HD60

1.00 1.01 1.00

G*FA060S21,24

1.00 1.00 1.00

G*FD060H24

1.00 1.00 1.00

G*FD061H24

1.01 1.01 1.01

MA20D

MC60D

1.00 1.00 1.00

Variable Speed
Furnace*

Coil

T.C.

S.C.

KW

P(C,V)9*D20

FC/MC/PC60D 0.99

0.96

0.99

PV8*C20

FC/PC60C 0.98

0.98

0.98

P(C,V)9*C20

FC/PC60C 0.99

0.96

0.99

PV8*C20

HC60 0.98

0.98

0.98

P(C,V)9*D20

HC60 0.99

0.96

0.99

PV8*C20

HD60 1.00

0.99

1.00

P(C,V)9*C20

HD60 0.99

0.96

0.99

P(C,V)9*D20

HD60 0.98

0.96

0.98

PV8*C20

MC61D 1.00

0.99

1.00

P(C,V)9*C20

MC61D 0.98

0.96

0.98

P(C,V)9*D20

MC61D 1.00

0.96

1.00

This manual is related to the following products: