beautypg.com

York H*RD018 THRU 060 User Manual

Page 10

background image

254892-YTG-C-0606

10

Unitary Products Group

— = Not applicable.

1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED

H2RD018S06

AV24 2,5,8,10,15

17 –

600

18.0

11.7

14.00

11.50

H2RD024S06

AV24 2,5,8,10,15

17 –

800

23.2

16.5

14.00

11.50

H2RD030S06

AV36 5,8,10,15,18

21 –

1000

30.0

21.2

14.00

11.50

H2RD036S06

AV36 5,8,10,15,18

21 –

1200

35.2

25.0

14.00

11.50

AV/SV48 5,8,10,15,18,20,25

24

1200 35.8 25.0

13.75

11.00

H2RD042S06

AV/SV48 5,8,10,15,18,20,25

24

1400 40.5 29.1

14.00

11.50

H2RD048S06

AV/SV48 5,8,10,15,18,20,25

24

1600 47.0 34.7

13.50

11.00

H2RD060S06

AV/SV60 5,8,10,15,18,20,25

24

1800 55.0 39.1

13.15

11.00

1 & 3 PH 13 SEER AC WITH AHP / F*FP / F*FV

H2RD018S06

AHP18 2,5,8

17

650

17.7

12.3

13.00

11.00

AHP24 2,5,8,10

17 –

655

17.9

12.5

13.50

11.00

F*FP024 5,8,10

17 –

650

17.5

12.2

13.00

11.00

H2RD024S06

AHP24 2,5,8,10

17 –

830

23.0

16.8

13.00

11.00

AHP30 5,8,10

17

795

23.6

17.0

13.00

11.00

F*FP024 5,8,10

17 –

800

23.0

16.8

13.00

11.00

F*FP030 5,8,10,15

17 –

800

23.0

16.8

13.00

11.00

H2RD030S06

AHP30 5,8,10

17

1015

30.0

21.9

13.00

11.00

AHP36 5,8,10,15,18

17 –

1040

30.0

22.6

13.50

11.00

F*FP036 5,8,10,15,19

21

1000

29.6

21.3

13.00

11.00

H1RD030S(25,46)

AHP30 5,8,10

17

1015

29.7

21.7

13.00

11.00

AHP36 5,8,10,15,18

17 –

1040

29.7

22.4

13.50

11.00

F4FP036 5,8,10,15,19

21

1000

29.3 21.1

13.00

11.00

H2RD036S06

AHP36 5,8,10,15,18

17 –

1235

35.0

27.2

13.50

11.00

AHP42 5,8,10,15,18

21 –

1255

35.0

27.5

13.50

11.00

AHP/SHP60 5,8,10,15,20,25 24

1200 36.0

26.7 14.00

11.50

F*FP040 5,8,10,15

21 –

1200

34.8

25.4

13.00

11.00

H1RD036S(25,46)

AHP36 5,8,10,15,18

17 –

1235

34.7

27.0

13.50

11.00

AHP42 5,8,10,15,18

21 –

1255

34.7

27.3

13.50

11.00

AHP/SHP60 5,8,10,15,20,25 24

1200 35.7

26.5 14.00

11.50

F*FP040 5,8,10,15

24 –

1200

34.5

25.2

13.00

11.00

H2RD042S06

AHP42 5,8,10,15,18

21 –

1485

41.0

31.0

13.00

11.00

AHP/SHP48 5,8,10,15,20 24

1400

42.0 30.7

13.50

11.00

AHP/SHP60 5,8,10,15,20,25 24

1400 40.5

33.2 14.00

11.50

F*FP048 5,8,10,15

24 –

1400

41.0

31.0

13.00

11.00

H1RD042S(25,46)

AHP42 5,8,10,15,18

21 –

1485

40.0

30.3

13.00

11.00

AHP/SHP48 5,8,10,15,20 24

1400

41.0 30.0

13.50

11.00

AHP/SHP60 5,8,10,15,20,25 24

1400 39.5

32.5 14.00

11.50

F4FP048 5,8,10,15

24 –

1400

40.0

30.3

13.00

11.00

H2RD048S06

F*FV060 5,8,10,15,20,25

24

1600

47.5 36.9

13.50

11.00

AHP/SHP48 5,8,10,15,20 24

1675

47.0 36.8

13.00

11.00

AHP/SHP60 5,8,10,15,20,25 24

1600 47.0

36.2 13.75

11.00

H1RD048S(25,46)

AHP/SHP48 5,8,10,15,20 24

1675

46.0 36.1

13.00

11.00

AHP/SHP60 5,8,10,15,20,25 24

1600 46.0

35.5 13.75

11.00

H2RD060S06

F*FV060 5,8,10,15,20,25

24

1850

55.0 40.3

13.20

11.00

AHP/SHP60 5,8,10,15,20,25 24

1850 55.0

40.3 13.00

11.00

H1RD060S(25,46)

AHP/SHP60 5,8,10,15,20,25 24

1850 54.0

39.6 13.00

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

MODEL

AIR HANDLER

COIL MODEL

1

COOLING

MODEL

ELECTRIC
HEAT KW

2

W

RATED

CFM

NET MBH

SEER

EER

TOTAL

SENS.

This manual is related to the following products: