beautypg.com

Figure 31 basic setting > switch setup, Table 10 basic setting > switch setup – ZyXEL Communications GS-3012F/3012 User Manual

Page 74

background image

Chapter 7 Basic Setting

GS-3012/GS-3012F User’s Guide

74

Figure 31 Basic Setting > Switch Setup

The following table describes the labels in this screen.

Table 10 Basic Setting > Switch Setup

LABEL

DESCRIPTION

VLAN Type

Choose 802.1Q or Port Based. The VLAN Setup screen changes depending on

whether you choose 802.1Q VLAN type or Port Based VLAN type in this screen.

See

Chapter 8 on page 83

for more information.

Bridge Control

Protocol

Transparency

Select Active to allow the Switch to handle bridging control protocols (STP for

example). You also need to define how to treat a BPDU in the Port Setup screen.

MAC Address

Learning

MAC address learning reduces outgoing traffic broadcasts. For MAC address

learning to occur on a port, the port must be active.

Aging Time

Enter a time from 10 to 3000 seconds. This is how long all dynamically learned MAC

addresses remain in the MAC address table before they age out (and must be

relearned).

GARP Timer: Switches join VLANs by making a declaration. A declaration is made by issuing a Join

message using GARP. Declarations are withdrawn by issuing a Leave message. A Leave All

message terminates all registrations. GARP timers set declaration timeout values. See the chapter on

VLAN setup for more background information.

Join Timer

Join Timer sets the duration of the Join Period timer for GVRP in milliseconds. Each

port has a Join Period timer. The allowed Join Time range is between 100 and

65535 milliseconds; the default is 200 milliseconds. See the chapter on VLAN setup

for more background information.

Leave Timer

Leave Time sets the duration of the Leave Period timer for GVRP in milliseconds.

Each port has a single Leave Period timer. Leave Time must be two times larger

than Join Timer; the default is 600 milliseconds.

Leave All Timer

Leave All Timer sets the duration of the Leave All Period timer for GVRP in

milliseconds. Each port has a single Leave All Period timer. Leave All Timer must be

larger than Leave Timer.