Table 32 SNMP InterfaceTraps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
linkup
linkUp
1.3.6.1.6.3.1.1.5.4
This trap is sent when the
Ethernet link is up.
LinkDownEventClear
ES-315:
1.3.6.1.4.1.890.1.5.8.41.27.2.2
ES-315-F:
1.3.6.1.4.1.890.1.5.8.42.27.2.2
This trap is sent when the
Ethernet link is up.
linkdown
linkDown
1.3.6.1.6.3.1.1.5.3
This trap is sent when the
Ethernet link is down.
LinkDownEventOn
ES-315:
1.3.6.1.4.1.890.1.5.8.41.27.2.1
ES-315-F:
1.3.6.1.4.1.890.1.5.8.42.27.2.1
This trap is sent when the
Ethernet link is down.
Table 33 AAA Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
authentication authenticationFailure
1.3.6.1.6.3.1.1.5.5
This trap is sent when
authentication fails due to incorrect
user name and/or password.
AuthenticationFailureEventOn ES-315:
1.3.6.1.4.1.890.1.5.8.41.27.2.1
ES-315-F:
1.3.6.1.4.1.890.1.5.8.42.27.2.1
This trap is sent when
authentication fails due to incorrect
user name and/or password.
Table 34 SNMP IP Traps
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
ping
pingProbeFailed
1.3.6.1.2.1.80.0.1
This trap is sent when a single ping probe
fails.
pingTestFailed
1.3.6.1.2.1.80.0.2
This trap is sent when a ping test
(consisting of a series of ping probes) fails.
pingTestCompleted
1.3.6.1.2.1.80.0.3
This trap is sent when a ping test is
completed.
traceroute
traceRoutePathChange
1.3.6.1.2.1.81.0.1
This trap is sent when the path to a target
has changed from a previously determined
path.
traceRouteTestFailed
1.3.6.1.2.1.81.0.2
This trap is sent when a traceroute test
fails.
traceRouteTestCompleted
1.3.6.1.2.1.81.0.3
This trap is sent when a traceroute test is
completed.