18. If you want to change the Gateway IP address shown, press
screen.
19. As done above, finish editing the Gateway IP address, then press
edit session and save the results, or press
Remember, that this must be the address of the router that allows you to connect to
remote IP networks. If it is not set correctly, you will not be able to reach your
iPump from remote networks, nor will you be able to do Return Path to the uplink
control system using this LAN port.
20. When done, press
ready to access the iPump 6420 from your web browser.
2.4.2.
Setup through the Front-Panel
This subsection gives you a checklist of items to setup or check to get your iPump 6420 on
the carrier and ready for satellite-based network control. Very few items are suggested for user
setup, because normally Compel will control must unit settings, and the web interface is much
more fully-featured (and thus recommended). These instructions are fairly terse, and, if any
difficulty, please refer to the general guide on the Front-Panel interface in Chapter 3. In some
cases, control of some or all of the following parameters has been disabled by a factory setting.
In this case, it was assumed that the unit was setup well enough to lock onto the carrier and
receive Compel network commands when first supplied the correct antenna connection. You
may then reference section 2.5 to see if the indications all show OK, and, if not, use the
Troubleshooting guide in Chapter 4.
Check/set LNB LO:
1. Start or return to the LCD Home screen is reached (see subsection 2.5.1).
2. Move to Unit Setup same level; select that
3. Move to Transport In Setup same level; select that
4. Move to LNB Setup same level; select that
5. For LNB Type, select either “Local Osc” (which is typical) or “Universal/ASTRA”
for special European satellites
6. Leave LO Type set to Custom Freq, all versions below 420
7. Move to LO Custom Freq and set it to either 5150 or 10750 MHz, if domestic
(consult with satellite provider outside US)
Check/set RF carrier settings:
1. Start or return to the LCD Home screen is reached (see subsection 2.5.1).
2. Move to Unit Setup same level; select that
3. Move to Transport In Setup same level; select that
4. Move to Current Channel; select that
5. Move to Symbol Format; select and edit as necessary. “QPSK” is std DVB-S1-
QPSK.
6. Move to FEC Ratio; select and edit as necessary.
7. Move to Downlink Frequency; select and edit as necessary
8. Move to Transp. Data Rate; select and edit as necessary OR
9. Move to Transp. Symb Rate; select and edit as necessary