Wegener Communications 6420 User Manual
Page 123
iPump 6420 User’s Manual
www.wegener.com
800070-01 Rev B
Appendix 2, Page 119
MAX-ACCESS
read-only
STATUS mandatory
::= { settingsGroupEntry 1 }
-- M_SYMBOL_FORMAT
symbolFormat OBJECT-TYPE
SYNTAX INTEGER {
asi(0)
qpsk(2)
psk8(3)
qam16(4)
turboqpsk(5)
turbopsk8(6)
turboqam16(7)
dvbs2qpsk(8)
dvbs2psk8(9)
}
MAX-ACCESS
read-only
STATUS mandatory
::= { settingsGroupEntry 2 }
-- M_INPUT_NUMBER
inputNumber OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS
read-only
STATUS mandatory
::= { settingsGroupEntry 3 }
-- M_CARRIER_FREQUENCY
carrierFrequency OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS
read-only
STATUS mandatory
DESCRIPTION
"Units (Mhz) / Factor (.001)"
::= { settingsGroupEntry 4 }
-- M_DATA_RATE
dataRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS
read-only
STATUS mandatory
::= { settingsGroupEntry 5 }
-- M_FEC_RATE
fecRate OBJECT-TYPE
SYNTAX INTEGER {
fec12(0)
fec23(1)
fec34(2)
fec56(3)
fec78(4)
fec89(5)
fec14(6)
turbo1fec34(7)
turbo2fec34(8)
fec13(9)