2.1.

Unpacking and Inspection

Carefully unpack the unit and its ac power cord and inspect for obvious signs of physical

damage that might have occurred during shipment. Also locate the bag of accessories, including
special cable pigtails and adaptors. Any damage claims must be reported to the carrier
immediately. Be sure to check the package contents carefully for important documents and
materials.

Note: Please save the packing materials and original shipping containers in case you must

later return the unit for repair. Packing these units in other containers in such a way that they are
damaged will void your warranty.

2.2.

Location and Mounting

The

iPump 6420

should be mounted in a standard 19-inch equipment rack. After mounting,

maintain a clean, dry environment for the unit.

Precautions

DANGER

To avoid damage to this and other equipment, or personal injury, the following items

should be strictly observed.

Elevated Operating Ambient

When equipment is installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than the room ambient temperature.
Therefore, consideration should be given to the ambient air temperature within the rack, and
not just inside the room, when deciding if the maximum recommended ambient operating
temperature (T

MRA

) is being met.

Reduced Air Flow

Equipment should be installed such that airflow required for safe operation of the equipment
is not compromised. To ensure adequate air flow, the

iPump 6420

should be arranged in a

rack with at least one empty rack unit between it and adjacent equipment and with adequate
clearance around both side vents.

Mechanical Loading

Mounting of the equipment in a rack should be such that a hazardous condition is not
produced by uneven loading. This unit is moderately heavy, so total rack loading must be
considered. Also, do not rest any unsupported equipment on your

iPump 6420

.

DANGER

Circuit Overloading

Consideration should be given to the connection of the equipment to the supply circuit and
the effect that overloading of circuits could have on overcurrent protection and supply
wiring. Ensure that the total rack or breaker power consumption does not exceed the limits
of the ac branch circuit. Appropriate consideration of equipment ratings should be used
when addressing this concern.

Reliable Earthing

Reliable earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit
(use of power strips, chassis ground lugs, etc.).

WARNING:

FCC-Mandated Suppression of Radio Frequency Emissions

This is a

Class A

product. In a domestic environment this product may cause radio

interference for which the user may need to take mitigating action.

If the Ethernet port has a cable connected to it, that cable must be properly shielded
and grounded to minimize RF emissions that could interfere with nearby equipment.