Front panel message possible cause – Wegener Communications 6420 User Manual

Page 134

background image

iPump 6420 User’s Manual

www.wegener.com

800070-01 Rev B

Appendix 3, Page 130

Front Panel Message

Possible Cause

No ID Tag found

No carrier ID tag found on newly-acquired carrier; if carrier ID
tag match is required, cannot access this Transport

No LAN detected

No Ethernet network detected at LAN port

No Modem Dial Tone

No dial tone on phone line

No PAT

No PAT (Program Association Table) found in initial Verify
Transport [if a warning, while occurring & carrier/ASI still locked]

No PMT

No PMT (Program Map Table) found for Program listed in PAT

No PPP Connection

PPP connection couldn't be established.

No Signal

No carrier lock and no RF power detected at RF input

No valid software

At unit boot-up, boot loader detects no valid application present to
load and run; unit will be inoperative & needs to be returned for
service

PAT Disappeared

PAT lost after first being verified

Playlist Doesn't Exist

Playlist to play doesn't exist

PMT Disappeared

PMT disappears or becomes corrupt

Program not found

Requested program number not listed in current PAT

Recovery

Auto-Recovery in progress

Reverted to B-up app

User-requested application failed self-test and Unit reverted to
Backup application [until next commanded app switch]

Sec Micro no resp

Secure micro cannot be accessed at bootup in order to verify unit
serial number

Using backup setting

Current settings derived from successful Auto- Recovery [until
local or network user setting command]

Unit overheating

Unit temperature sensor detects very high internal temperature;
operator needs to check that ventilation fans have not failed, vents
are clear, and ambient temperature is not exceeded