Cat system computer control – Vertex Standard FT-1000MP User Manual
Page 98
Page 96
O
PERATING
M
ANUAL
CAT System Computer Control
Opcode Command Chart (3)
Parameter Description
Switch Antenna Tuner ON (T = 01H) or OFF (T = 00H)
Start Antenna Tuning
Switch Dual Receive ON (D = 01H) or OFF (D = 00H)
Switch Simplex Operation (R = 00H), Minus Shift (R = 01H),
or Plus Shift (R = 02H) for Repeater Operation
Copy Data Display in VFO-A or VFO-B.
Enter new operating frequency in F1 ~ F4, in BCD format:
see text for example.
Select filter bandwidth for selected IF (see below):
VFO-A
VFO-B
IF (VFO-A)
THRU: X4 = 04
6.0 kHz: X4 = 84
Both: X1 = 00
2.4 kHz: X4 = 00 2.4 kHz: X4 = 80
8.2 MHz: X1 = 01
2.0 kHz: X4 = 01 2.0 kHz: X4 = 81
455 kHz: X1 = 02
500 Hz: X4 = 02 500 Hz: X4 = 82
250 Hz: X4 = 03 250 Hz: X4 = 83
Tag memory channels 1 through 99 (X = 01H ~ 6CH), to be
skipped (S = 01H) or included (S = 00H) while scanning.
Step frequency of VFO-A UP (T = 00H) or DOWN (T = 01H)
Select one of 33 CTCSS subaudible tones
where E = 00H ~ 20H
E = 00H 67.0 Hz E = 0BH 118.8 Hz E = 16H 173.8 Hz
E = 01H 71.9 Hz E = 0CH 123.0 Hz E = 17H 179.9 Hz
E = 02H 77.0 Hz E = 0DH 127.3 Hz E = 18H 186.2 Hz
E = 03H 82.5 Hz E = 0EH 131.8 Hz E = 19H 192.8 Hz
E = 04H 88.5 Hz E = 0FH 136.5 Hz E = 1AH 203.5 Hz
E = 05H 94.8 Hz E = 10H 141.3 Hz E = 1BH 210.7 Hz
E = 06H 100.0 Hz E = 11H 146.2 Hz E = 1CH 218.1 Hz
E = 07H 103.5 Hz E = 12H 151.4 Hz E = 1DH 225.7 Hz
E = 08H 107.2 Hz E = 13H 156.7 Hz E = 1EH 233.6 Hz
E = 09H 110.9 Hz E = 14H 162.2 Hz E = 1FH 241.8 Hz
E = 0AH 114.8 Hz E = 15H 167.9 Hz E = 20H 250.3 Hz
Instruct radio to return digitized indications of various meter
level readings and front panel control settings (4 repeated
bytes, and F7H) selected by:
M = 00H Main S-Meter
M = 87H TUN Meter
M = 01H Sub S-Meter
M = F0H Shuttle Jog Dial
M = 80H PO Meter
M = F1H CW Pitch Setting
M = 81H ALC Meter
M = F2H Remote Control A/D Level
M = 83H IC Meter
M = F3H SHIFT Setting
M = 84H VCC Meter
M = F4H WIDTH Setting
M = 85H SWR Meter
M = F5H EDSP Contour Selection
M = 86H MIC Meter
M = F6H EDSP NR Selection
Set offset for RPT shift, valid values are
0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.
X1 is 10’s & 100’s of Hz
X2 is 1’s & 10’s of kHz
X3 is must be 00H, 01H, or 02H X4 is must be 00H
Opcode
5th
81H
82H
83H
84H
85H
8AH
8CH
8DH
8EH
90H
F7H
F9H
4th
T
–
D
R
–
F4
X4
X
T
E
–
X4
3rd
–
–
–
–
–
F3
–
S
–
E
–
X3
2rd
–
–
–
–
–
F2
–
–
–
E
–
X2
1st
–
–
–
–
–
F1
X1
–
–
E
–
X1
Command
or Key
TUNER
Tuner Start
Dual Operation
[RPT]
[A
u
B]
Set SUB
VFO-B
Operating Freq.
BANDWIDTH
2nd & 3rd IF
Filter Selection
MEM. Channel
Scan Skip
Step VFO-A
UP/DOWN
CTCSS
Encoder
Tone Frequency
Select
Read Meter &
Panel Controls
Repeater
Offset
Parameter Bytes