beautypg.com

Cat system computer control – Vertex Standard FT-1000MP User Manual

Page 98

background image

Page 96

O

PERATING

M

ANUAL

CAT System Computer Control

Opcode Command Chart (3)

Parameter Description

Switch Antenna Tuner ON (T = 01H) or OFF (T = 00H)

Start Antenna Tuning

Switch Dual Receive ON (D = 01H) or OFF (D = 00H)

Switch Simplex Operation (R = 00H), Minus Shift (R = 01H),
or Plus Shift (R = 02H) for Repeater Operation

Copy Data Display in VFO-A or VFO-B.

Enter new operating frequency in F1 ~ F4, in BCD format:
see text for example.

Select filter bandwidth for selected IF (see below):

VFO-A

VFO-B

IF (VFO-A)

THRU: X4 = 04

6.0 kHz: X4 = 84

Both: X1 = 00

2.4 kHz: X4 = 00 2.4 kHz: X4 = 80

8.2 MHz: X1 = 01

2.0 kHz: X4 = 01 2.0 kHz: X4 = 81

455 kHz: X1 = 02

500 Hz: X4 = 02 500 Hz: X4 = 82
250 Hz: X4 = 03 250 Hz: X4 = 83

Tag memory channels 1 through 99 (X = 01H ~ 6CH), to be
skipped (S = 01H) or included (S = 00H) while scanning.

Step frequency of VFO-A UP (T = 00H) or DOWN (T = 01H)

Select one of 33 CTCSS subaudible tones
where E = 00H ~ 20H

E = 00H 67.0 Hz E = 0BH 118.8 Hz E = 16H 173.8 Hz
E = 01H 71.9 Hz E = 0CH 123.0 Hz E = 17H 179.9 Hz
E = 02H 77.0 Hz E = 0DH 127.3 Hz E = 18H 186.2 Hz
E = 03H 82.5 Hz E = 0EH 131.8 Hz E = 19H 192.8 Hz
E = 04H 88.5 Hz E = 0FH 136.5 Hz E = 1AH 203.5 Hz
E = 05H 94.8 Hz E = 10H 141.3 Hz E = 1BH 210.7 Hz
E = 06H 100.0 Hz E = 11H 146.2 Hz E = 1CH 218.1 Hz
E = 07H 103.5 Hz E = 12H 151.4 Hz E = 1DH 225.7 Hz
E = 08H 107.2 Hz E = 13H 156.7 Hz E = 1EH 233.6 Hz
E = 09H 110.9 Hz E = 14H 162.2 Hz E = 1FH 241.8 Hz
E = 0AH 114.8 Hz E = 15H 167.9 Hz E = 20H 250.3 Hz

Instruct radio to return digitized indications of various meter
level readings and front panel control settings (4 repeated
bytes, and F7H) selected by:

M = 00H Main S-Meter

M = 87H TUN Meter

M = 01H Sub S-Meter

M = F0H Shuttle Jog Dial

M = 80H PO Meter

M = F1H CW Pitch Setting

M = 81H ALC Meter

M = F2H Remote Control A/D Level

M = 83H IC Meter

M = F3H SHIFT Setting

M = 84H VCC Meter

M = F4H WIDTH Setting

M = 85H SWR Meter

M = F5H EDSP Contour Selection

M = 86H MIC Meter

M = F6H EDSP NR Selection

Set offset for RPT shift, valid values are
0 ~ 500 kHz in 1-kHz step. Use BCD format for X2 ~ X4.

X1 is 10’s & 100’s of Hz

X2 is 1’s & 10’s of kHz

X3 is must be 00H, 01H, or 02H X4 is must be 00H

Opcode

5th

81H

82H

83H

84H

85H

8AH

8CH

8DH

8EH

90H

F7H

F9H

4th

T

D

R

F4

X4

X

T

E

X4

3rd

F3

S

E

X3

2rd

F2

E

X2

1st

F1

X1

E

X1

Command

or Key

TUNER

Tuner Start

Dual Operation

[RPT]

[A

u

B]

Set SUB

VFO-B

Operating Freq.

BANDWIDTH

2nd & 3rd IF

Filter Selection

MEM. Channel

Scan Skip

Step VFO-A

UP/DOWN

CTCSS

Encoder

Tone Frequency

Select

Read Meter &

Panel Controls

Repeater

Offset

Parameter Bytes