beautypg.com

Installing internal accessories, Tcxo u – Vertex Standard FT-1000MP User Manual

Page 114

background image

Page 112

O

PERATING

M

ANUAL

This section contains the installation procedures for

installable options available for the MARK-V FT-1000MP
Field
. A complete list of options and their correspond-
ing Yaesu P/N is provided on pages 5 and 6 of this
manual. Please check with your dealer for pricing and
availability.

Installing Internal Accessories

TCXO U

NIT

The Temperature-Compensated Crystal Oscillator

is the heart of the master reference oscillator used
throughout the transceiver. An optional TCXO unit is
available for installation into the MARK-V FT-1000MP
Field
. The ±0.25-ppm TCXO-6 replaces the factory-
installed TCXO unit, and it provides enhanced fre-
quency stability compared to the standard ±0.5-ppm
module.

If you also have the optional YF-115C Sub Receiver

filter, now would be a good time to install it, as its mount-
ing position is also exposed during the TCXO installa-
tion procedures.

TCXO-6 Installation

r Disconnect all cables from the transceiver.
r Referring to Figure 1, remove the carrying handle

and its two screws (

Ú

), then remove the four

screws (

ð

) on each side of the transceiver, and

the seven screws (

¢

) from the bottom of the trans-

ceiver, then lift off the bottom cover.

r Referring to Figure 2, remove the three screws (

Æ

)

along the top edge of the rear panel, then lift off the
top cover.

r Locate the factory-installed TCXO UNIT in the front

right corner of the chassis (see drawing below), and
remove the wiring connector from the board. Use a
small screwdriver to pry up the rear edge of the
connector, and avoid pulling on the wires.

r Remove the four screws at the corners of the board,

and remove the factory-installed TCXO UNIT.

r Position the new TCXO-6 in place, and use the

same screws just removed to affix the new board
in place.

r Reinstall the wiring connector.

This completes the installation; replace the covers

and carrying handle with its screws removed above
(unless installing other options now).

Figure 2

Figure 1

YF-115C

Mounting Location

TCXO-6 Mounting Location
(Replace with the factory-installed TCXO Unit)